3MVHBTapes  
Application Techniques  
Clean: Most substrates are best prepared by cleaning with a 50:50 mixture of isopropyl alcohol (IPA*) and  
water prior to applying 3M™ VHB™ Tapes.  
Exceptions to the general procedure that may require additional surface preparation include:  
• Heavy Oils: A degreaser or solvent-based cleaner may be required to remove heavy oil or grease from a  
surface and should be followed by cleaning with IPA/water.  
• Abrasion: Abrading a surface, followed by cleaning with IPA/water, can remove heavy dirt or oxidation  
and can increase surface area to improve adhesion.  
• Adhesion Promoters: Priming a surface can significantly improve initial and ultimate adhesion to many  
materials such as plastics and paints.  
• Porous surfaces: Most porous and fibered materials such as wood, particleboard, concrete, etc. need to be  
sealed to provide a unified surface.  
• Unique Materials: Special surface preparation may be needed for glass and glass-like materials, copper  
and copper containing metals, and plastics or rubber that contain components that migrate (e.g. plasticizers).  
Refer to 3M Technical Bulletin “Surface Preparation for 3M™ VHB™ Tape Applications” for additional  
details and suggestions. (70-0704-8701-5)  
*Note: These cleaner solutions contain greater than 250 g/l of volatile organic compounds (VOC). Please  
consult your local Air Quality Regulations to be sure the cleaner is compliant. When using solvents,  
be sure to follow the manufacturer’s precautions and directions for use when handling such materials.  
Pressure: Bond strength is dependent upon the amount of adhesive-to-surface contact developed. Firm  
application pressure develops better adhesive contact and helps improve bond strength. Typically, good surface  
contact can be attained by applying enough pressure to insure that the tape experiences approximately 15 psi  
(100 kPa) pressure. Either roller or platen pressure can be used. Note that rigid surfaces may require 2 or 3 times  
that much pressure to make the tape experience 15 psi.  
Temperature: Ideal application temperature range is 70°F to 100°F (21°C to 38°C). Pressure sensitive  
adhesives use viscous flow to achieve substrate contact area. Minimum suggested application temperatures:  
• 50°F (10°C): 3M™ VHB™ Tapes 4950, 5952, 4910, 4952, 4611, 4622 families.  
• 60°F (15°C): 3M™ VHB™ Tapes 4941, 4945 families.  
• 32°F (0°C): 3M™ VHB™ Tape 4951 families.  
Note: Initial tape application to surfaces at temperatures below these suggested minimums is not  
recommended because the adhesive becomes too firm to adhere readily. However, once properly  
applied, low temperature holding is generally satisfactory.  
To obtain good performance with all 3M™ VHB™ Tapes, it is important to ensure that the surfaces are dry  
and free of condensed moisture.  
Time: After application, the bond strength will increase as  
the adhesive flows onto the surface (also referred to as “wet out”).  
At room temperature approximately 50% of ultimate bond  
strength will be achieved after 20 minutes, 90% after 24 hours  
and 100% after 72 hours. This flow is faster at higher temperatures  
and slower at lower temperatures. Ultimate bond strength can be  
achieved more quickly (and in some cases bond strength can be  
increased) by exposure of the bond to elevated temperatures  
(e.g. 150°F [66°C] for 1 hour). This can provide better adhesive  
wetout onto the substrates. Abrasion of the surfaces or the use of  
primers/ adhesion promoters can also have the effect of increasing  
bond strength and achieving ultimate bond strength more quickly.  
Bond Typical Build vs. Time  
PERCENT OF FULL BOND  
100  
80  
60  
40  
20  
ROOM TEMP  
50°F  
150°F or ABRADE  
0
20 MIN 1 HOUR  
72 HOURS  
24 HOURS  