欢迎访问ic37.com |
会员登录 免费注册
发布采购

C2655 参数 Datasheet PDF下载

C2655图片预览
型号: C2655
PDF下载: 下载PDF文件 查看货源
内容描述: 机架和机柜安装转换器 [Rack & Cabinet Mounting Converters]
分类和应用: 转换器
文件页数/大小: 8 页 / 201 K
品牌: A-DATA [ A-DATA TECHNOLOGY ]
 浏览型号C2655的Datasheet PDF文件第1页浏览型号C2655的Datasheet PDF文件第3页浏览型号C2655的Datasheet PDF文件第4页浏览型号C2655的Datasheet PDF文件第5页浏览型号C2655的Datasheet PDF文件第6页浏览型号C2655的Datasheet PDF文件第7页浏览型号C2655的Datasheet PDF文件第8页  
19” Subracks & Redundant Systems
Front View
Description
In addition to a complete range of individual
power supplies we are able to offer a ‘total
solution’ to your power requirements.
Subracks can be configured as 3U, 6U or 9U and
multiples thereof, allowing any mix of units
including ‘hot swap’ redundant systems.
The wide range of options available include input
fuses, circuit breakers, decoupling diodes, RFI
filters, front panels and full system wiring.
Outputs are via DIN rail screw terminals and are
configured to customers requirements to
incorporate DC OK relay contacts, input and
output connections and any other options.
Rack & Cabinet Mounting Converters 150-12 k Watts C Series
DC-DC Converters
Rear View
Please contact the sales office for a
quotation.
Example
The photographs show a typical system
containing a C624-DD.DR which could be
configured with another unit to provide a
dual redundant system.
i.e. Specification could be:
DC Input: 18-36 V
DC Output: 24 V @ 18 A, dual redundant
Each unit is rated at 18 Amps and is connected
in parallel via decoupling diodes and set up to
current share. In the event of a psu failure the DC
OK alarm relay trips, the failed psu can be
identified by its front panel LED and the psu
replaced without power shut down ie. ‘Hot Swap’.
A full system schematic is provided with each
system as shown below, the size and orientation
of connectors can be specified by the customer.
Sample Schematic
Standard Options
- see over for integral psu
options
3U subrack, 215 or 275 mm deep
6U subrack, 215 or 275 mm deep
6U subrack, configured as 2 x 3U
9U subrack, configured as 3 x 3U
9U subrack, configured as 1 x 3U, 1 x 6U
H15 mating connectors and wiring
DIN rail terminal strip at rear
Input Fuse
up to 25 A
up to 63 A
MCB, single pole
up to 25 A
up to 40 A
up to 63 A
up to 25 A
up to 40 A
up to 63 A
www.xpplc.com
MCB, dual pole
Decoupling Diodes on Heatsink 2 x 50 A
2 x 80 A
RFI filter, 20-40 dB reduction
The above demonstrates a typical schematic as supplied with each
system. It shows two units connected in parallel incorporating
options DD (Decoupling Diodes) and DR (DC-OK Relay).
up to 10 A
up to 20 A
Front panels, plain or drilled all sizes
Tel: +33 (0)820 801 401
F
Tel: +41 (0)56 483 34 00
CH