3.3 Imaging Characteristics Tested Procedures
3.3.1. Saturation signal
1 ) Set 60.8 lx illumination condition, then measure the signal output.
2 ) Detect the average value of the test area
3 ) See figure 1 below for the Test area
3.3.2. Sensitivity
1) Set 1.0 lx illumination condition, then measure the signal output.
2) Detect sensitivity with the following formula.
3) See figure 1 below for the Test area
3.3.3. Smear
1) Set 0 lx illumination condition, then measure the signal output without readout PD ( IMAFE0 ).
2) Set 1900 lx illumination condition measure the signal output readout PD (IMAGE1 ).
3) Subtract IMAGE0 from IMAGE1 as a reference level if the signal output.
4) Divide Smear test area to 20 areas, and detect the average value in each area.
5) Select the maximum value from the average values ( Smear_max ).
6) Detect Smear with the following formula.
7) See figure 2 below for the Test area.