IMP5226
1
Recommended Operating Conditions
Parameter
Termpwr Voltage
Signal Line Voltage
Disconnect Input Voltage
Operating Junction Temperature Range – IMP5226C
Symbol
V
TERM
Min
4.0
0
0
0
Typ
Max
5.5
5.0
V
TERM
125
Units
V
V
V
°C
5226_t02.eps
Note:
2. Recommended operating conditions indicate the range over which the device is functional.
Electrical Characteristics
Unless otherwise specified, these specifications apply at an ambient operating temperature of T
A
=
25°C. TermPwr = 4.75V. Low duty cycle
pulse testing techniques are used which maintains junction and case temperatures equal to the ambient temperature.
Parameter
Output High Voltage
TermPwr Supply Current
Symbol Conditions
V
OUT
I
CC
All data lines = Open
All data lines = 0.2V
DISCONNECT Pins > 2.0V
Min
2.65
Typ
2.85
10
424
50
Max
15
450
150
–24
–10
1
Units
V
mA
µA
mA
µA
µA
MHz
mA
5226_t03.eps
Output Current
Disconnect Input Current
Output Leakage Current
Channel Bandwidth
Termination Sink Current, per Channel
I
OUT
I
IN
I
OL
BW
I
SINK
V
OUT
= 0.5V
DISCONNECT Pins = 0V
DISCONNECT Pins > 2.0V, V
O
= 0.2V
–20
–22
35
V
OUT
= 4V
7
© 2000 IMP, Inc.
Data Communications
3