RELIABILITY  
Specified Value  
Item  
Test Methods and Remarks  
AL02, AL03 Type  
AL04 Type  
AL05 Type  
16. Resistance to Solvent  
17. Thermal shock  
Please avoid the ultrasonic cleaning of this product.  
L/L Within 10% L/L Within 10% L/L Within 5%  
Conditions for 1 cycle  
Q 30min.  
Q/Q Within 30% Q 15min.  
Step  
Temperature(˚C)  
Duration(min)  
30  
within 3  
30  
within 3  
+0  
1
2
-25  
3
-3  
Room temperature  
+2  
+85  
-0  
3
4
3
Room temperature  
Number of cycles: 5 cycles  
Recovery: At least 1 hr of recovery under the standard condition  
after the removal from test chamber, followed by the measurement  
within 2 hrs.  
18. Damp Heat  
L/L Within 10% L/L Within 10% L/L Within 5%  
Q 30min. Q/Q Within 30% Q 15min.  
- Temperature: 40 2˚C  
- Duration: 1000hrs  
- Humidity: 90 to 95% RH  
- Recovery: At least 1 hr of recovery under the standard condition  
after the removal from test chamber, followed by the measurement  
within 2 hrs.  
19. Loading under Tensile  
Damp Heat  
L/L Within 10% L/L Within 10% L/L Within 5%  
Q 30min. Q/Q Within 30% Q 15min.  
- Temperature: 40 2˚C  
- Duration: 1000hrs  
- Humidity: 90 to 95% RH  
- Applied current: Rated current  
- Recovery: At least 1 hr of recovery under the standard condition  
after the removal from test chamber, followed by the measurement  
within 2 hrs.  
20. Loading at High  
Temperature  
L/L Within 10% L/L Within 10% L/L Within 5%  
Q 30min. Q/Q Within 30% Q 15min.  
- Temperature: 85 2˚C  
- Applied current: Rated current  
- Duration: 1000hrs  
- Recovery: At least 1 hr of recovery under the standard condition  
after the removal from test chamber, followed by the measurement  
within 2 hrs.  
21. Low Temperature  
Life Test  
L/L Within 10% L/L Within 10% L/L Within 5%  
Q 30min. Q/Q Within 30% Q 15min.  
- Temperature: -25 2˚C  
- Applied current: Rated current  
- Duration: 1000hrs  
- Recovery: At least 1 hr of recovery under the standard condition  
after the removal from test chamber, followed by the measurement  
within 2 hrs.  
Note on standard condition: “standard condition” referred to herein is defined as follows.  
5 to 35˚C of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.  
When there are questions concerning measurement results: In order to provide correlation data, the test shall be conducted under condition of 20 2˚C of temperatue,  
45 to 85% relative humidity and 86 to 106kPa of air pressure Unless otherwise specified, all the tests are conducted under the “standard condition”  
PACKING  
Inner Box  
Size(m/m)  
Out Box  
Taping  
Lead  
Style  
Type  
Item  
Size(m/m)  
(W × H ×L)  
Weight  
(100µH)  
Quantity  
Quantity  
(W × H ×L)  
AL02  
ALC02  
ALN02  
AL03  
8.5kg  
TA  
TB  
TR  
26m/m  
52m/m  
52m/m  
50×65×252  
2,000  
285×260×455  
54,000  
9.5kg  
11kg  
AL02  
70×65×265  
2,500  
285×250×455  
6kg  
ALC02,  
ALN02  
45,000  
70×85×265  
70×110×355  
70×110×355  
2,500  
2,500  
2,000  
285×305×455  
330×260×485  
7kg  
6kg  
AL03  
AL04  
AL05  
AL02  
ALC02  
AL03  
AL04  
30,000  
24,000  
10kg  
5,000  
50,000  
14kg  
280×280  
(A×A)  
460×320×600  
4,000  
2,500  
40,000  
25,000  
14kg  
16kg  