LPL0411 Series
http://www.abco.co.kr
Leaded type
▼Shape
& Dimensions / Recommended Solder Land Pattern
(Dimensions in mm)
6.0max
0
100
0±2
13.0Max
7.0±0.3
18.0±0.5
4.0±0.3
12.7±0.3
5.0±0.3
▼Electrical
Characteristics
Ordering
Code
LPL0411T-100M
LPL0411T-150K
LPL0411T-220K
LPL0411T-470K
LPL0411T-101K
Inductance
L
(uH)
10
15
22
±10
47
100
Freq.
F
(MHz)
7.96
DC Resistance(Ω)
Rdc
(Max.)
0.45
1.30
1.50
Rated DC
current(A)
0.46
0.33
0.27
0.20
0.15
Tol.
(%)
±20
2.52
2.20
3.30
▼
Test Equipments
. L : Agilent E4980A Precision LCR Meter
. Rdc : HIOKI 3540 mΩ HiTESTER
. Idc : Agilent 4284A LCR Meter + Agilent 42841A Bias Current Source
▼
Test Condition
. Idc(The saturation current) :
△L≤
10% typical at rated current
※
Rated DC current : Idc
▼
Operating Temperature Range
-20 ~ +85℃ (Including self-generated heat)