LPL0919 Series
http://www.abco.co.kr
Leaded type
▼Shape
& Dimensions / Recommended Solder Land Pattern
(Dimensions in mm)
100
10.0max
0±2
0
19.0Max
7.0±0.3
18.0±0.5
4.0±0.3
12.7±0.3
5.0±0.3
▼Electrical
Characteristics
Ordering
Code
Inductance
L
(uH)
1000
±10
LPL0919T-333K
33000
1
40.00
0.036
Freq.
F
(KHz)
DC Resistance(Ω)
Rdc
(Max.)
1.30
Rated DC
current(A)
Tol.
(%)
LPL0919T-102K
0.230
▼
Test Equipments
. L : Agilent E4980A Precision LCR Meter
. Rdc : HIOKI 3540 mΩ HiTESTER
. Idc : Agilent 4284A LCR Meter + Agilent 42841A Bias Current Source
▼
Test Condition
. Idc(The saturation current) :
△L≤
10% typical at rated current
※
Rated DC current : Idc
▼
Operating Temperature Range
-20 ~ +85℃ (Including self-generated heat)