ACE301
High-precision Low Voltage Detector
Technology
ACE301C/N34XX + (3.4V)
(Topt=25℃, Unless otherwise specified.)
Reference data
Symbol
Parameter
Detector Threshold
Conditions
Unit
Min.
3.332
Typ.
Max.
3.468
-VDET
VHYS
3.4
V
V
Detector Threshold Hysteresis
0.068 0.136 0.204
ISS
Current Consumption
Maximum Operating Voltage
Minimum Operating Voltage
VDD=5.0V
0.5
1
uA
V
VDDH
VDDL
10
0.5
V
Nch
0.01
1.0
0.05
mA
VDS=0.05V, VDD=0.7V
IOUT
Output Current
Pch
2.0
mA
uS
VDS=-2.1V, VDD=4.50V
TPLH
Output Delay Time
20
ACE301C/N44XX + (4.4V)
(Topt=25℃, Unless otherwise specified.)
Reference data
Symbol
Parameter
Conditions
Unit
Min.
Typ.
Max.
-VDET
VHYS
Detector Threshold
4.312
4.4
4.488
V
V
Detector Threshold Hysteresis
0.088 0.176 0.264
ISS
Current Consumption
Maximum Operating Voltage
Minimum Operating Voltage
VDD=6.4V
0.5
1
uA
V
VDDH
VDDL
10
0.5
V
Nch
0.01
1.5
0.05
mA
VDS=0.05V, VDD=0.7V
IOUT
Output Current
Pch
3.0
mA
uS
VDS=-2.1V, VDD=8.0V
TPLH
Output Delay Time
20
VER 1.4
5