欢迎访问ic37.com |
会员登录 免费注册
发布采购

5962-9684101HXC 参数 Datasheet PDF下载

5962-9684101HXC图片预览
型号: 5962-9684101HXC
PDF下载: 下载PDF文件 查看货源
内容描述: 28 V / 100 W和积分EMI滤波器的DC / DC转换器 [28 V/100 W DC/DC Converters with Integral EMI Filter]
分类和应用: 转换器局域网
文件页数/大小: 20 页 / 262 K
品牌: AD [ ANALOG DEVICES ]
 浏览型号5962-9684101HXC的Datasheet PDF文件第1页浏览型号5962-9684101HXC的Datasheet PDF文件第2页浏览型号5962-9684101HXC的Datasheet PDF文件第3页浏览型号5962-9684101HXC的Datasheet PDF文件第5页浏览型号5962-9684101HXC的Datasheet PDF文件第6页浏览型号5962-9684101HXC的Datasheet PDF文件第7页浏览型号5962-9684101HXC的Datasheet PDF文件第8页浏览型号5962-9684101HXC的Datasheet PDF文件第9页  
ADDC02812DA/ADDC02815DA
ABSOLUTE MAXIMUM RATINGS*
PIN DESCRIPTIONS
INHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V dc, –0.5 V dc
SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V dc, –0.5 V dc
I
SHARE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V dc, –0.5 V dc
TEMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V dc, –0.3 V dc
Lead Soldering Temp (10 sec) . . . . . . . . . . . . . . . . . . . +300°C
Storage Temperature . . . . . . . . . . . . . . . . . . –65°C to +150°C
Maximum Junction Temperature . . . . . . . . . . . . . . . . +150°C
Maximum Case Operating Temperature . . . . . . . . . . . +125°C
*Absolute maximum ratings are limiting values, to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability under any of these conditions is not necessarily implied. Exposure of
absolute maximum rating conditions for extended periods of time may affect
device reliability.
Pin
No. Name
1
–SENSE
Function
Feedback loop connection for remote sensing
output voltage. Must always be connected for
proper operation.
Feedback loop connection for remote sensing
output voltage. Must always be connected
for proper operation.
Adjusts output voltage setpoint.
Indicates output voltage is within
±
5% of
nominal. Active high referenced to –SENSE
(Pin 1).
Low level dc auxiliary voltage supply refer-
enced to input return (Pin 10).
Power supply disable. Active low and refer-
enced to input return (Pin 10).
Clock synchronization input for multiple
units; referenced to input return (Pin 10).
Current share pin which allows paralleled
units to share current typically within
±
5% at
full load; referenced to input return (Pin 10).
Case temperature indicator and temperature
shutdown override; referenced to input return
(Pin 10).
Input Return.
+28 V Nominal Input Bus.
+12 V dc Output (ADDC02812DA).
+15 V dc Output (ADDC02815DA).
+12 V dc Output (ADDC02812DA).
+15 V dc Output (ADDC02815DA).
Output Return.
Output Return.
–12 V dc Output (ADDC02812DA).
–15 V dc Output (ADDC02815DA).
–12 V dc Output (ADDC02812DA).
–15 V dc Output (ADDC02815DA).
2
+SENSE
3
4
ADJUST
STATUS
ORDERING GUIDE
Model
ADDC02812DAKV
ADDC02812DATV
5962-9684101HXC
(ADDC02812DATV/QMLH)
ADDC02815DAKV
ADDC02815DATV
5962-9684201HXC
(ADDC02815DATV/QMLH)
Operating
Temperature
Range (Case)
–40°C to +85°C
–55°C to +90°C
5
Package
Description
Hermetic
Hermetic
6
7
8
V
AUX
INHIBIT
SYNC
I
SHARE
–55°C to +125°C Hermetic
–40°C to +85°C Hermetic
–55°C to +90°C Hermetic
–55°C to +125°C Hermetic
9
TEMP
EXPLANATION OF TEST LEVELS
Test Level
10
11
12
13
14
15
16
17
–V
IN
+V
IN
+V
OUT
+V
OUT
V
COMMON
V
COMMON
–V
OUT
–V
OUT
I
II
– 100% production tested.
– 100% production tested at +25°C, and sample tested
at specified temperatures.
III – Sample tested only.
IV – Parameter is guaranteed by design and characterization
testing.
V – Parameter is a typical value only.
VI – All devices are 100% production tested at +25°C. 100%
production tested at temperature extremes for military
temperature devices; guaranteed by design and charac-
terization testing for industrial devices.
PIN CONFIGURATION
1
17
TOP
VIEW
11
12
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the ADDC02812DA/ADDC02815DA feature proprietary ESD protection circuitry, permanent
damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper
ESD precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. A