OP37
ABSOLUTE MAXIMUM RATINGS
4
ORDERING GUIDE
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 V
Internal Voltage (Note 1 ) . . . . . . . . . . . . . . . . . . . . . . . . . 22 V
Output Short-Circuit Duration . . . . . . . . . . . . . . . . . Indefinite
Differential Input Voltage (Note2) . . . . . . . . . . . . . . . . . 0.7 V
Differential Input Current (Note 2) . . . . . . . . . . . . . . . . 25 mA
Storage Temperature Range . . . . . . . . . . . . . –65°C to +150°C
Operating Temperature Range
OP37A . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to +1 25°C
OP37E (Z) . . . . . . . . . . . . . . . . . . . . . . . . . . –25°C to +85°C
OP37E, OP-37F (P) . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
OP37G (P, S, Z) . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Lead Temperature Range (Soldering, 60 sec) . . . . . . . . 300°C
Junction Temperature . . . . . . . . . . . . . . . . . . –45°C to +150°C
Package Type
3
JA
JC
T
A
= 25°C
V
OS
MAX
(µV)
25
25
60
100
100
CerDIP
8-Lead
OP37AZ*
OP37EZ
Plastic
8-Lead
OP37EP
OP37FP*
OP37GP
OP37GS
Operating
Temperature
Range
MIL
IND/COM
IND/COM
XIND
XIND
OP37GZ
*Not
for new design, obsolete, April 2002.
Unit
°C/W
°C/W
°C/W
8-Lead Hermetic DIP (Z) 148
8-Lead Plastic DIP (P)
103
8-Lead SO (S)
158
16
43
43
NOTES
1
For supply voltages less than 22 V, the absolute maximum input voltage is equal
to the supply voltage.
2
The OP37’s inputs are protected by back-to-back diodes. Current limiting resistors
are not used in order to achieve low noise. If differential input voltage exceeds 0.7 V,
the input Current should be limited to 25 mA.
3
JA
is specified for worst case mounting conditions, i.e.,
JA
is specified for device
in socket for TO, CerDIP, P-DIP, and LCC packages;
JA
is specified for device
soldered to printed circuit board for SO package.
4
Absolute maximum ratings apply to both DICE and packaged parts, unless
otherwise noted.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the OP37 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions
are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–2–
REV. A