AMC76386
RECOMMENDED OPERATING CONDITIONS
Parameter
Input Voltage
Load Current (with adequate heat sinking)
Input Capacitor (V
IN
to GND)
Output Capacitor with ESR of 10Ω max., (V
OUT
to GND)
Operating ambient temperature range
Operating junction temperature
Symbol
V
IN
I
O
Recommended Operating Conditions
Min.
3.0
5
0.1
1.0
-40
Typ.
Max.
10
450
Units
V
mA
µF
µF
O
C
O
C
T
A
T
J
85
125
ELECTRICAL CHARACTERISTICS
Unless otherwise specified, V
IN
= V
OUT(TYP)
+
1V, I
O
= 10mA, C
OUT
= 4.7µF, T
A
=25
O
C, and are for DC characteristics
only. (Low duty cycle pulse testing techniques are used which maintains junction and case temperatures equal to the
ambient temperature.)
Parameter
Symbol
V
OUT1
V
OUT2
V
O
∆V
OI
∆V
OL
Test Conditions
I
O
= 10mA
V
IN
= (V
OUT
+
0.5V) to 8V
10mA
≤
I
O
≤100mA
Load regulation
10mA
≤
I
O
≤
300mA
10mA
≤
I
O
≤
450mA
I
O
= 100mA
Dropout Voltage
Ground Pin Current
Current Limit
Output Voltage Temperature
Coefficient
∆V
I
Q
I
CL
I
O
= 300mA
I
O
= 450mA
I
O
= 10mA~450mA
V
IN
= V
OUT
+ 0.5V
I
O
=100mA, -40
O
C
≤
T
J
≤
125
O
C
450
±100
AMC76386
Min
2.450
3.234
Typ
2.500
3.300
0.1
15
45
95
120
360
540
8
Max
2.550
3.366
0.3
30
80
140
180
540
810
20
µA
mA
ppm/
O
C
mV
mV
Units
V
%/V
Output Voltage
Line Regulation
Copyright
©
2006 ADDtek Corp.
3
DD055_A
-- JUNE 2006