AMS1585  
APPLICATION HINTS  
This current is normally the specified minimum load current of  
10mA. Because IADJ is very small and constant it represents a  
small error and it can usually be ignored.  
Connected as shown, RP is not multiplied by the divider ratio.  
Using 16-gauge wire the parasitic line resistance is about 0.004Ω  
per foot, translating to 4mV/ft at 1A load current. It is important to  
keep the positive lead between regulator and load as short as  
possible and use large wire or PC board traces.  
AMS1585  
VOUT  
VIN  
Thermal Considerations  
IN  
OUT  
ADJ  
VREF  
R1  
R2  
The AMS1585 series have internal power and thermal limiting  
circuitry designed to protect the device under overload conditions.  
However maximum junction temperature ratings should not be  
exceeded under continuous normal load conditions. Careful  
consideration must be given to all sources of thermal resistance  
from junction to ambient, including junction-to-case, case-to-heat  
sink interface and heat sink resistance itself. To ensure safe  
operating temperatures and reflect more accurately the device  
temperature, new thermal resistance specifications have been  
developed. Unlike older regulators with a single junction-to-case  
thermal resistance specification, the data section for these new  
regulators provides a separate thermal resistance and maximum  
junction temperature for both the Control Section and the Power  
Transistor. Calculations for both temperatures under certain  
conditions of ambient temperature and heat sink resistance and to  
ensure that both thermal limits are met.  
IADJ  
50µA  
V
OUT = VREF (1+ R2/R1)+IADJR2  
Figure 1. Basic Adjustable Regulator  
Load Regulation  
True remote load sensing it is not possible to provide, because the  
AMS1585 is a three terminal device. The resistance of the wire  
connecting the regulator to the load will limit the load regulation.  
The data sheet specification for load regulation is measured at the  
bottom of the package. Negative side sensing is a true Kelvin  
connection, with the bottom of the output divider returned to the  
negative side of the load.  
The best load regulation is obtained when the top of the resistor  
divider R1 is connected directly to the case not to the load. If R1  
were connected to the load, the effective resistance between the  
regulator and the load would be:  
Junction-to-case thermal resistance is specified from the IC  
junction to the bottom of the case directly below the die. This is  
the lowest resistance path for the heat flow. In order to ensure the  
best possible thermal flow from this area of the package to the  
heat sink proper mounting is required. Thermal compound at the  
case-to-heat sink interface is recommended.  
A thermally  
conductive spacer can be used, if the case of the device must be  
electrically isolated, but its added contribution to thermal  
resistance has to be considered.  
RP x ( R2+R1 ) , RP = Parasitic Line Resistance  
R1  
RP  
PARASITIC  
LINE RESISTANCE  
AMS1585  
VIN  
IN  
OUT  
ADJ  
RL  
R1*  
R2*  
*CONNECT R1 TO CASE  
CONNECT R2 TO LOAD  
Figure 2. Connections for Best Load Regulation  
Advanced Monolithic Systems, Inc. www.advanced-monolithic.com Phone (925) 443-0722 Fax (925) 443-0723