 浏览型号OR3T125-6PS208I的Datasheet PDF文件第57页浏览型号OR3T125-6PS208I的Datasheet PDF文件第58页浏览型号OR3T125-6PS208I的Datasheet PDF文件第59页浏览型号OR3T125-6PS208I的Datasheet PDF文件第60页浏览型号OR3T125-6PS208I的Datasheet PDF文件第62页浏览型号OR3T125-6PS208I的Datasheet PDF文件第63页浏览型号OR3T125-6PS208I的Datasheet PDF文件第64页浏览型号OR3T125-6PS208I的Datasheet PDF文件第65页  
Data Sheet  
June 1999  
ORCA Series 3C and 3T FPGAs  
The TAPC generates control signals that allow capture,  
shift, and update operations on the instruction and data  
registers. In the capture operation, data is loaded into  
the register. In the shift operation, the captured data is  
shifted out while new data is shifted in. In the update  
operation, either the instruction register is loaded for  
instruction decode, or the boundary-scan register is  
updated for control of outputs.  
Special Function Blocks (continued)  
ORCA Series TAP Controller (TAPC)  
The ORCA Series TAP controller (TAPC) is a 1149.1/  
D1 compatible test access port controller. The 16 JTAG  
state assignments from the IEEE 1149.1/D1 specifica-  
tion are used. The TAPC is controlled by TCK and  
TMS. The TAPC states are used for loading the IR to  
allow three basic functions in testing: providing test  
stimuli (Update-DR), test execution (Run-Test/Idle),  
and obtaining test responses (Capture-DR). The TAPC  
allows the test host to shift in and out both instructions  
and test data/results. The inputs and outputs of the  
TAPC are provided in the table below. The outputs are  
primarily the control signals to the instruction register  
and the data register.  
The test host generates a test by providing input into  
the ORCA Series TMS input synchronous with TCK.  
This sequences the TAPC through states in order to  
perform the desired function on the instruction register  
or a data register. Figure 39 provides a diagram of the  
state transitions for the TAPC. The next state is deter-  
mined by the TMS input value.  
TEST-LOGIC-  
RESET  
1
Table 15.  
TAP Controller Input/Outputs  
0
1
1
1
RUN-TEST/  
IDLE  
SELECT-  
DR-SCAN  
SELECT-  
IR-SCAN  
Symbol  
I/O  
Function  
Test Mode Select  
Test Clock  
Powerup Reset  
BSCAN Reset  
0
0
0
TMS  
TCK  
PUR  
I
I
I
I
O
O
O
O
O
O
O
O
O
1
1
CAPTURE-DR  
CAPTURE-IR  
0
0
SHIFT-DR  
1
0
0
SHIFT-IR  
1
0
0
PRGM  
TRESET  
Select  
Enable  
Capture-DR  
Capture-IR  
Shift-DR  
Shift-IR  
Update-DR  
Update-IR  
Test Logic Reset  
1
1
EXIT1-DR  
0
EXIT1-IR  
0
Select IR (High); Select-DR (Low)  
Test Data Out Enable  
Capture/Parallel Load-DR  
Capture/Parallel Load-IR  
Shift Data Register  
Shift Instruction Register  
Update/Parallel Load-DR  
Update/Parallel Load-IR  
PAUSE-DR  
PAUSE-IR  
1
EXIT2-DR  
1
1
EXIT2-IR  
1
0
0
UPDATE-DR  
UPDATE-IR  
1
0
1
0
5-5370(F)  
Figure 39. TAP Controller State Transition Diagram  
Lucent Technologies Inc.  
61