Data Sheet
June 1999
ORCA
Series 3C and 3T FPGAs
Programmable Clock Manager (PCM)
(continued)
Table 31. PCM Control Registers
(continued)
Bit #
Function
Register 4—DLL 1x Duty-Cycle Programming
Duty-Cycle/Delay Selection for Duty Cycle/Delays Less Than or Equal to 50%.
The duty-
Bits [2:0]
cycle/delay is (value of bits [7:6]) * 25% + ((value of bits [2:0]) + 1) * 3.125%. See the description
for bits [7:6].
Duty-Cycle/Delay Selection for Duty Cycle/Delays Greater Than 50%.
The duty-cycle/delay
Bits [5:3]
is (value of bits [7:6]) * 25% + ((value of bits [5:3]) + 1) * 3.125%. See the description for bits [7:6].
Master Duty Cycle Control:
Bits [7:6]
00: duty cycle 3.125% to 25%
01: duty cycle 28.125% to 50%
10: duty cycle 53.125% to 75%
11: duty cycle 78.125% to 96.875%
Example: A 40.625% duty cycle, bits [7:0] are 01 XXX 100, where X is a don’t care because the
duty cycle is not greater than 50%.
Example: The
PCM
output clock should be delayed 96.875% (31/32) of the input clock period.
Bits [7:0] are 11110XXX, which is 78.125% from bits [7:6] and 18.75% from bits [5:3]. Bits [2:0]
are don’t care (X) because the delay is greater than 50%.
Register 5—Mode Programming
DLL/PLL Mode Selection Bit.
0 = DLL, 1 = PLL. Default is DLL mode.
Bit 0
Reserved.
Bit 1
PLL Phase Detector Feedback Input Selection Bit.
0 = feedback signal from routing/
Bit 2
ExpressCLK,
1 = feedback from programmable delay line output. Default is 0. Has no effect in
DLL mode.
Reserved.
Bit 3
1x/2x Clock Selection Bit for DLL Mode.
0 = 1x clock output, 1 = 2x clock output. Default is 1x
Bit 4
clock output. Has no effect in PLL mode.
Reserved.
Bits [7:5]
Lucent Technologies Inc.