Insulation and Safety Related Specifications
Parameter
Min. External Clearance
(External Air Gap)
Min. External Creepage
(External Tracking Path)
Min. Internal Clearance
(Internal Plastic Gap)
Symbol
L(IO1)
L(IO2)
Value
9.6
10.0
1.0
Units
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Through insulation distance conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity
The shortest distance around the border
between two different insulating materials
measured between the emitter and detector
DIN IEC 112/VDE 0303 PART 1
Material group (DIN VDE 0110)
Min. Internal Creepage
(Internal Tracking Path)
Comparative Tracking Index
Isolation Group
CTI
4.0
mm
200
IIIa
V
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
VDE 0884 (06.92) Insulation Characteristics (Option #050 Only)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage
600 V rms
For rated mains voltage
1000 V rms
Climatic Classification (DIN IEC 68 part 1)
Pollution Degree (DIN VDE 0110 Part 1/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
PR
= 1.875 x V
IORM
, 100% Production Test with
t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
PR
= 1.5 x V
IORM
, Type and sample test, t
m
= 60 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety-Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 11)
Case Temperature
Current (Input Current I
F
, P
S
= 0)
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
V
IORM
V
PR
Symbol
Characteristic
I-IV
I-III
55/100/21
2
1414
2651
V
peak
V
peak
Unit
V
PR
2121
V
peak
V
IOTM
8000
V
peak
T
S
I
S
P
S,OUTPUT
R
S
150
400
700
>10
9
°C
mA
mW
*Refer to the front of the Optocoupler section of the current catalog for a more detailed description of VDE 0884 and other product
safety regulations.
Note:
Optocouplers providing safe electrical separation per VDE 0884 do so only within the safety-limiting values to which they are
qualified. Protective cut-out switches must be used to ensure that the safety limits are not exceeded.
1-421