型号: AIC1383BPSTR
PDF下载: 下载PDF文件 查看货源
内容描述: 3A终端稳压器 [3A TERMINATION REGULATOR]
分类和应用: 稳压器
文件页数/大小: 9 页 / 499 K
品牌: AIC [ ANALOG INTERGRATIONS CORPORATION ]
 浏览型号AIC1383BPSTR的Datasheet PDF文件第1页浏览型号AIC1383BPSTR的Datasheet PDF文件第2页浏览型号AIC1383BPSTR的Datasheet PDF文件第4页浏览型号AIC1383BPSTR的Datasheet PDF文件第5页浏览型号AIC1383BPSTR的Datasheet PDF文件第6页浏览型号AIC1383BPSTR的Datasheet PDF文件第7页浏览型号AIC1383BPSTR的Datasheet PDF文件第8页浏览型号AIC1383BPSTR的Datasheet PDF文件第9页  
AIC1383B
TEST CIRCUIT
2.5
V
1
2
3
VIN
GND
VREF
VCNTL
AIC1383
B
4
VOUT
5
V
OUT
+
1.
25V
C
OUT
10µF
3.3
V
ELECTRICAL CHARACTERISTICS
(V
CNTL
=3.3V, V
IN
=2.5V, V
REF
=0.5V
IN
, C
OUT
=10µF, T
A
=25°C, unless otherwise specified) (Note 1)
PARAMETER
Input Voltage (DDR1/2)
(Note2)
Output Voltage
Output Voltage Offset
TEST CONDITIONS
Keep operate V
CNTL
≥V
IN
at
power on and off sequences
I
OUT
= 0mA
I
OUT
= 0mA
SYMBOL
V
IN
V
CNTL
V
OUT
V
OS
∆V
LOR
I
Q
I
CNTL
0
I
IL
3.2
4
-20
35
35
8
3
MIN.
1.6
3.0
TYP.
2.5
3.3
V
REF
20
45
45
30
10
1
6.5
MAX.
6
6
UNIT
V
V
mV
mV
µA
mA
µA
A
Load Regulation (DDR1/2) I
OUT
=0.1mA ~ +3A
(Note2)
Quiescent Current
I
OUT
=0.1mA ~ -3A
V
REF
<0.2V, V
OUT
= OFF
Operating Current of V
CNTL
No load
V
REF
Bias Current
Current Limit
THERMAL PROTECTION
Thermal Shutdown
Temperature
Thermal Shutdown
Hysteresis
3.3V≤V
CNTL
≤5V
Guaranteed by design
V
REF
=1.25V
T
SD
125
150
30
°C
°C
SHUTDOWN SPECIFICATIONS
Shutdown Threshold
Output ON (V
REF
=0V 1.25V)
Output OFF (V
REF
=1.25V 0V)
0.8
0.2
V
Note 1: Specifications are production tested at T
A
=25°C. Specifications over the -40°C to 85°C operating
temperature range are assured by design, characterization and correlation with Statistical Quality
Controls (SQC).
Note 2: DDR2 is not available for TO-263 package.
Note 3: V
OS
is the voltage measurement, which is defined as V
OUT
subtracted V
REF.
Note 4: Load regulation is measured at constant junction temperature, using pulse testing with a low ON time.
Note 5: Current limit is measured by pulsing a short time.
Note 6: For operate system safely; V
CNTL
must be always greater than V
IN
.
3