AIC1734
ELECTRICAL CHARACTERISTICS
erwise specified.)
PARAMETER
(T
A
=25°C, C
IN
=1µF, C
OUT
=1µF, unless oth-
TEST CONDITIONS
No Load
AIC1734-52
AIC1734-50
AIC1734-38
AIC1734-37
AIC1734-35
AIC1734-33
AIC1734-30
AIC1734-27
AIC1734-25
AIC1734-20
AIC1734-18
(Note 1)
I
L
=
1mA,
1.4V≤V
OUT
≤3.2V
3.3V≤V
OUT
≤5.2V
I
L
=0.1~300mA
1.4V≤V
OUT
≤3.9V
4.0V≤V
OUT
≤5.2V
V
IN
=7V, V
OUT
=0V
4.0V≤V
OUT
≤5.2V
3.0V≤V
OUT
≤3.9V
2.5V≤V
OUT
≤2.9V
2.0V≤V
OUT
≤2.4V
1.4V≤V
OUT
≤1.9V
V
IN
=5~12V
V
IN
=7~12V
V
IN
=4V~12V
V
IN
=5.5V~12V
V
IN
=5V
V
IN
=7V
V
IN
=5.5~12V
V
IN
=5.5~12V
V
IN
=4.1~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
V
IN
=4.0~12V
MIN.
5.100
4.900
3.725
3.625
3.430
3.235
2.940
2.646
2.450
1.960
1.764
TYP.
5.200
5.000
3.800
3.700
3.500
3.300
3.000
2.700
2.500
2.000
1.800
50
3
3
7
15
MAX.
5.300
5.100
3.875
3.775
3.570
3.365
3.060
2.754
2.550
2.040
1.836
UNIT
Output Voltage
V
Output Voltage Tem-
perature Coefficiency
Line Regulation
Load Regulation
(Note 2)
Current Limit
(Note 3)
Dropout Voltage
(Note 4)
PPM/°C
10
10
20
40
mV
mV
mA
300
400
470
570
800
1260
55
55
80
80
I
L
=300mA
mV
Ground Current
I
O
=0.1mA~I
MAX
1.4V≤V
OUT
≤3.9V
4.0V≤V
OUT
≤5.2V
µA
Note 1:
Note 2:
Note 3:
Note 4:
Note5:
Guaranteed by design.
Regulation is measured at constant junction temperature, using pulse testing with a low ON time.
Current limit is measured by pulsing a short time.
Dropout voltage is defined as the input to output differential at which the output voltage drops
100mV.
Specifications are guaranteed by Statistical Quality Controls (SQC), with no production test proved,
when operating temperature ranges from -40°C to 85°C.
4