ꢀ ELECTRICAL CHARACTERISTICS (TA=25°C, CIN=1µF, COUT=1µF, unless oth-
erwise specified.)
PARAMETER
TEST CONDITIONS
MIN.
TYP.
MAX.
UNIT
No Load
AIC1734-52
AIC1734-50
AIC1734-38
AIC1734-37
AIC1734-35
AIC1734-33
AIC1734-30
AIC1734-27
AIC1734-25
AIC1734-20
AIC1734-18
VIN=5.5~12V
VIN=5.5~12V
VIN=4.1~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
VIN=4.0~12V
5.100
4.900
3.725
3.625
3.430
3.235
2.940
2.646
2.450
1.960
1.764
5.200
5.000
3.800
3.700
3.500
3.300
3.000
2.700
2.500
2.000
1.800
5.300
5.100
3.875
3.775
3.570
3.365
3.060
2.754
2.550
2.040
1.836
Output Voltage
V
Output Voltage Tem-
perature Coefficiency
(Note 1)
50
PPM/°C
IL=1mA,
Line Regulation
1.4V≤VOUT≤3.2V
3.3V≤VOUT≤5.2V
IL=0.1~300mA
1.4V≤VOUT≤3.9V
4.0V≤VOUT≤5.2V
VIN=4V~12V
3
3
10
10
mV
VIN=5.5V~12V
Load Regulation
(Note 2)
VIN=5V
VIN=7V
7
20
40
mV
mA
15
Current Limit
(Note 3)
VIN=7V, VOUT=0V
300
4.0V≤VOUT≤5.2V
3.0V≤VOUT≤3.9V
2.5V≤VOUT≤2.9V
2.0V≤VOUT≤2.4V
1.4V≤VOUT≤1.9V
400
470
Dropout Voltage
(Note 4)
IL=300mA
570
mV
800
1260
IO=0.1mA~IMAX
1.4V≤VOUT≤3.9V
4.0V≤VOUT≤5.2V
Ground Current
VIN=5~12V
VIN=7~12V
55
55
80
80
µA
Note 1:
Note 2:
Note 3:
Note 4:
Guaranteed by design.
Regulation is measured at constant junction temperature, using pulse testing with a low ON time.
Current limit is measured by pulsing a short time.
Dropout voltage is defined as the input to output differential at which the output voltage drops
100mV.
Note5:
Specifications are guaranteed by Statistical Quality Controls (SQC), with no production test proved,
when operating temperature ranges from -40°C to 85°C.