欢迎访问ic37.com |
会员登录 免费注册
发布采购

AIC1742-30BPVBG 参数 Datasheet PDF下载

AIC1742-30BPVBG图片预览
型号: AIC1742-30BPVBG
PDF下载: 下载PDF文件 查看货源
内容描述: 低噪声,低静态电流, 150mA线性稳压器,具有噪声旁路 [Low Noise, Low Quiescent Current, 150mA Linear Regulator with Noise Bypass]
分类和应用: 稳压器
文件页数/大小: 12 页 / 617 K
品牌: AIC [ ANALOG INTERGRATIONS CORPORATION ]
 浏览型号AIC1742-30BPVBG的Datasheet PDF文件第4页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第5页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第6页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第7页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第8页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第10页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第11页浏览型号AIC1742-30BPVBG的Datasheet PDF文件第12页  
AIC1742
DETAILED DESCRIPTION OF TECHNICAL TERMS
DROPOUT VOLTAGE (V
DROP
)
The dropout voltage is defined as the difference
between the input voltage and output voltage at
which the output voltage drops 100mV. Below
this value, the output voltage will fall as the input
voltage reduces. It depends on the load current
and junction temperature.
STANDBY CURRENT (I
STBY
)
Standby current is the current flowing into the
regulator when the output is shutdown by setting
V
SHDN
at 0V and V
IN
at 8 V.
CURRENT LIMIT (I
IL
)
Current limiting of AIC1742 monitors and controls
the maximum output current, in case of a shorted
output. It protects device from the damage
resulting from any unexpected current.
RIPPLE REJECTION (RR)
Ripple rejection is the ability of the regulator to
reduce voltage ripple, which comes from input, at
output terminal. It is specified with a signal of
0.5V
P-P
at 1KHz frequency applying to input,
output capacitor at 2.2µF as well as a noise
bypass of 0.1µF. Ripple rejection, expressed in
dB, is the ratio of output ripple to input.
THERMAL PROTECTION
Thermal sensor protects device when the
junction temperature exceeds T
J
= +155ºC. It
signals shutdown logic, turning off pass transistor
and allowing IC to cool down. After the IC’s
junction temperature cools by 15ºC, the thermal
sensor will turn the pass transistor back on.
Thermal protection is designed to protect the
device in the event of fault conditions. For a
continuous operation, do not exceed the absolute
maximum junction-temperature rating of T
J
=
150ºC, or damage may occur to the device.
LINE REGULATION
Line regulation is the ability of the regulator to
maintain a constant output voltage as the input
voltage changes. The line regulation is specified
as the input voltage changes from V
IN
= V
OUT
+
1V to V
IN
= 8V and I
OUT
= 1mA.
LOAD REGULATION
Load regulation is the ability of the regulator to
maintain a constant output voltage as the load
current changes. A pulsed measurement with an
input voltage set to V
IN
= V
OUT
+ V
DROP
can
minimize temperature effects. The load
regulation is specified by the output current
ranging from 0.1mA to 150mA.
QUIESCENT CURRENT (I
Q
)
Quiescent current is the current flowing through
ground pin with no output load.
GROUND CURRENT (I
GND
)
Ground current is the current flowing through the
ground pin with output load.
9