欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM100HB-2424S-UZ 参数 Datasheet PDF下载

AM100HB-2424S-UZ图片预览
型号: AM100HB-2424S-UZ
PDF下载: 下载PDF文件 查看货源
内容描述: 100瓦|半砖DC- DC转换器 [100 Watt | Half Brick DC-DC Converter]
分类和应用: 转换器
文件页数/大小: 4 页 / 398 K
品牌: AIMTEC [ AIMTEC ]
 浏览型号AM100HB-2424S-UZ的Datasheet PDF文件第2页浏览型号AM100HB-2424S-UZ的Datasheet PDF文件第3页浏览型号AM100HB-2424S-UZ的Datasheet PDF文件第4页  
Series AM100HB-UZ
100 Watt | Half Brick DC-DC Converter
FEATURES:
RoHS compliant
Wide 2:1 Input range
Very low ripple and noise
On/Off Control and Trim Function
Regulated output
High efficiency
Operating temperature range: -40 to +85ºC
1500VDC I/O Isolation
Models
Single output
Model
AM100HB-2403S-UZ
AM100HB-2405S-UZ
AM100HB-2412S-UZ
AM100HB-2415S-UZ
AM100HB-2424S-UZ
AM100HB-2428S-UZ
AM100HB-2448S-UZ
AM100HB-4803S-UZ
AM100HB-4805S-UZ
AM100HB-4812S-UZ
AM100HB-4815S-UZ
AM100HB-4824S-UZ
AM100HB-4848S-UZ
AM100HB-11005S-UZ
AM100HB-11012S-UZ
AM100HB-11015S-UZ
AM100HB-11024S-UZ
AM100HB-11048S-UZ
Input Voltage (V)
18-36
18-36
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
36-72
66-160
66-160
66-160
66-160
66-160
Output Voltage
(V)
3.3
5
12
15
24
28
48
3.3
5
12
15
24
48
5
12
15
24
48
Output Current max (A)
20
20
8.3
6.7
4.2
3.6
2.1
20
20
8.3
6.7
4.2
2.1
20
8.3
6.7
4.2
2.1
Input Filter
π
type
π
type
L type
L type
L type
L type
L type
π
type
π
type
L type
L type
L type
L type
π
type
L type
L type
L type
L type
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated
output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Remote Control
Logic Low
Turn On Time
Start-up Delay Time
Nominal
24
48
110
CNTRL open or connect to +Vin
CNTRL connect to –Vin
Typical
18-36
36-72
66-160
On
Off
Maximum
Units
VDC
0.4
10
150
V
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Tested Input / Case Ivoltage
Tested Output / Case voltage
Conditions
1 Min
1 Min
1 Min
Typical
1500
500
500
Maximum
Units
VDC
VDC
VDC
Output Specifications
Parameters
Set point accuracy
Trim range
Dynamic Response
Short Circuit protection
Short Circuit restart
Over Temperature Protection
www.aimtec.com
F 054e R3.D
Conditions
200µs setting time
Typical
±1
±10
50-75% & 50-25% load
Continuous
Auto recovery
110
Maximum
3% of Vout
Units
%
%
Pk deviation
o
>105
115
C
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only