AT1453
Preliminary Product Information
Photoflash Capacitor Charger for DSC
Soft-Start Setting
The soft start operation is determined by the capacitor connected to the SS terminal. It can calculate the
soft start time Ts(s).
C
×
−
0 .3
V
∆
V
=
I
→
C
×
DUTY
=
1
µ
A
∆
t
∆
t
Ts
(
s
)
=
(
V
DUTY
−
0.3)
×
C
(
µ
F
)
Example: (Fig C)
R5=47K
V
DUTY
=0.790V
Ts(s)=(0.790-0.3)*1=0.49(sec)
CH1:V
OUT
CH2:SS CH3:DUTY CH4:I
BAT