3054  
MULTIPLEXED  
TWO-WIRE  
HALL-EFFECT SENSOR ICs  
SENSOR LOCATION  
FUNCTIONAL BLOCK DIAGRAM  
(±0.005” [0.13 mm] die placement)  
1
BUS  
ACTIVE AREA DEPTH  
0.015"  
0.090"  
0.38 mm  
2.29 mm  
NOM  
REG  
COMP  
COMP  
0.073"  
1.85 mm  
RESET  
CLOCK  
CMOS LOGIC  
SWITCH IN  
(OPTIONAL)  
3
A
BRANDED  
SURFACE  
1
2
3
2
GROUND  
Dwg. FH-009  
Dwg. MH-002-10A  
DEFINITION OF TERMS  
Sensor Address  
Sensor Quiescent Current Drain (IQ)  
Each bus sensor has a factory-specified predefined  
address. At present, allowable sensor addresses are  
integers from 01 to 30.  
The current drain of bus sensors when active but not  
addressed. IQH is the quiescent current drain when the  
sensor is not addressed and is at VH IQL is the quiescent  
current drain when the sensor is not addressed and is at  
LOW-to-HlGH Clock Threshold (VCLH  
)
VL. Note that IQL is greater than IQH  
.
Minimum voltage required during the positive-going  
transition to increment the bus address and trigger a  
diagnostic response from the bus sensors. This is also  
the maximum threshold of the on-chip comparator that  
Diagnostic Phase  
Period on the bus when the address voltage is at VH.  
During this period, a correctly addressed sensor responds  
by increasing its current drain on the bus. This response  
from the sensor is called the diagnostic response and  
the bus current increase is called the diagnostic current.  
monitors the supply voltage, VBUS  
.
HlGH-to-LOW Threshold (VHL)  
Maximum voltage required during the negative-going  
transition to trigger a signal current response from the bus  
sensors. This is also the maximum threshold of the  
on-chip comparator that monitors the supply voltage,  
Signal Phase  
Period on the bus when the address voltage is at VL.  
During this period, a correctly addressed sensor that  
detects a magnetic field greater than the magnetic oper-  
ate point, BOP, responds by maintaining a current drain of  
IS on the bus. This response from the sensor is called the  
signal response and the bus current is called the signal  
current.  
VBUS  
.
Bus HIGH Voltage (VH)  
Bus HIGH voltage during addressing. Voltage should  
be greater than VCLH  
.
Sensor Address Response Current (IS)  
Address LOW Voltage (VL)  
Sensor current during the diagnostic and the signal  
responses of the bus sensor. This is accomplished by  
enabling an internal constant-current source.  
Bus LOW voltage during addressing. Voltage should  
be greater than VRST and less than VCHL  
.
Bus Reset Voltage (VRST  
)
Voltage level while resetting sensors.