A3211 and  
A3212  
Micropower, Ultrasensitive  
Hall Effect Switch  
3211 MAGNETIC CHARACTERISTICS over operating voltage and temperature range (unless otherwise specified)  
Limits  
Characteristic  
Symbol  
Test Conditions  
Min.  
Typ.  
37  
Max.  
55  
Units  
G
BOPS  
BOPN  
BRPS  
BRPN  
BHYS  
South pole to branded side; B > BOP, VOUT = High (Output Off)  
North pole to branded side; B > BOP, VOUT = High (Output Off)  
South pole to branded side; B < BRP, VOUT = Low (Output On)  
North pole to branded side; B < BRP, VOUT = Low (Output On)  
Operate Points  
–55  
10  
–40  
31  
G
G
Release Points  
Hysteresis  
–34  
5.9  
–10  
G
|BOPx - BRPx  
|
G
NOTES: 1. Negative flux densities are defined as less than zero (algebraic convention), i.e., -50 G is less than +10 G.  
2. BOPx = operate point (output turns off); BRPx = release point (output turns on).  
3. Typical Data is at TA = +25°C and VDD = 2.75 V and is for design information only.  
4. 1 gauss (G) is exactly equal to 0.1 millitesla (mT).  
3212 MAGNETIC CHARACTERISTICS over operating voltage and temperature range (unless otherwise specified)  
Limits  
Characteristic  
Symbol  
Test Conditions  
Min.  
Typ.  
37  
Max.  
55  
Units  
G
BOPS  
BOPN  
BRPS  
BRPN  
BHYS  
South pole to branded side; B > BOP, VOUT = Low (Output On)  
North pole to branded side; B > BOP, VOUT = Low (Output On)  
South pole to branded side; B < BRP, VOUT = High (Output Off)  
North pole to branded side; B < BRP, VOUT = High (Output Off)  
Operate Points  
–55  
10  
–40  
31  
G
G
Release Points  
Hysteresis  
–34  
5.9  
–10  
G
|BOPx - BRPx  
|
G
NOTES: 1. Negative flux densities are defined as less than zero (algebraic convention), i.e., -50 G is less than +10 G.  
2. BOPx = operate point (output turns on); BRPx = release point (output turns off).  
3. Typical Data is at TA = +25°C and VDD = 2.75 V and is for design information only.  
4. 1 gauss (G) is exactly equal to 0.1 millitesla (mT).  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff, Box 15036  
5
Worcester, Massachusetts 01615-0036 (508) 853-5000  
www.allegromicro.com