A3211
and
A3212
Micropower, Ultrasensitive
Hall Effect Switch
3211 MAGNETIC CHARACTERISTICS
over operating voltage and temperature range (unless otherwise specified)
Characteristic
Operate Points
Release Points
Hysteresis
Symbol
B
OPS
B
OPN
B
RPS
B
RPN
B
HYS
Test Conditions
South pole to branded side; B > B
OP
, V
OUT
= High (Output Off)
North pole to branded side; B > B
OP
, V
OUT
= High (Output Off)
South pole to branded side; B < B
RP
, V
OUT
= Low (Output On)
North pole to branded side; B < B
RP
, V
OUT
= Low (Output On)
|B
OPx
- B
RPx
|
Limits
Min.
–
–55
10
–
–
Typ.
37
–40
31
–34
5.9
Max.
55
–
–
–10
–
Units
G
G
G
G
G
NOTES: 1. Negative flux densities are defined as less than zero (algebraic convention), i.e., -50 G is less than +10 G.
2. B
OPx
= operate point (output turns off); B
RPx
= release point (output turns on).
3. Typical Data is at T
A
= +25°C and V
DD
= 2.75 V and is for design information only.
4. 1 gauss (G) is exactly equal to 0.1 millitesla (mT).
3212 MAGNETIC CHARACTERISTICS
over operating voltage and temperature range (unless otherwise specified)
Characteristic
Operate Points
Release Points
Hysteresis
Symbol
B
OPS
B
OPN
B
RPS
B
RPN
B
HYS
Test Conditions
South pole to branded side; B > B
OP
, V
OUT
= Low (Output On)
North pole to branded side; B > B
OP
, V
OUT
= Low (Output On)
South pole to branded side; B < B
RP
, V
OUT
= High (Output Off)
North pole to branded side; B < B
RP
, V
OUT
= High (Output Off)
|B
OPx
- B
RPx
|
Limits
Min.
–
–55
10
–
–
Typ.
37
–40
31
–34
5.9
Max.
55
–
–
–10
–
Units
G
G
G
G
G
NOTES: 1. Negative flux densities are defined as less than zero (algebraic convention), i.e., -50 G is less than +10 G.
2. B
OPx
= operate point (output turns on); B
RPx
= release point (output turns off).
3. Typical Data is at T
A
= +25°C and V
DD
= 2.75 V and is for design information only.
4. 1 gauss (G) is exactly equal to 0.1 millitesla (mT).
Allegro MicroSystems, Inc.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
5