ACS758xCB
Thermally Enhanced, Fully Integrated, Hall Effect-Based
Linear Current Sensor IC with
100
μΩ
Current Conductor
Description (continued)
conductive path are electrically isolated from the signal leads (pins
1 through 3). This allows the ACS758 family of sensor ICs to be
used in applications requiring electrical isolation without the use of
opto-isolators or other costly isolation techniques.
The device is fully calibrated prior to shipment from the factory.
The ACS758 family is lead (Pb) free. All leads are plated with 100%
matte tin, and there is no Pb inside the package. The heavy gauge
leadframe is made of oxygen-free copper.
Selection Guide
Package
Part
Number
1
Terminals
Formed
Formed
Formed
Straight
Formed
Straight
Signal Pins
Formed
Formed
Formed
Straight
Formed
Straight
Primary Sampled
Current , I
P
(A)
±50
±100
±150
±200
Sensitivity
Sens (Typ.)
(mV/A)
40
20
13.3
10
T
OP
(°C)
–40 to 150
–40 to 125
–40 to 85
170 per bulk bag
Packing
2
ACS758LCB-050B-PFF-T
ACS758LCB-100B-PFF-T
ACS758KCB-150B-PFF-T
ACS758KCB-150B-PSS-T
ACS758ECB-200B-PFF-T
ACS758ECB-200B-PSS-T
1
Additional
2
Contact Allegro
leadform options available for qualified volumes
for additional packing options.
Absolute Maximum Ratings
Characteristic
Forward Supply Voltage
Reverse Supply Voltage
Working Voltage for Reinforced Isolation
Forward Output Voltage
Reverse Output Voltage
Output Source Current
Output Sink Current
Nominal Operating Ambient Temperature
Maximum Junction
Storage Temperature
Symbol
V
CC
V
RCC
V
WORKING
V
IOUT
V
RIOUT
I
OUT(Source)
I
OUT(Sink)
T
OP
T
J
(max)
T
stg
VIOUT to GND
VCC to VIOUT
Range E
Range K
Range L
Voltage applied between pins 1-3 and 4-5;
tested at 3000 VAC for 1 minute according to
UL standard 60950-1
Notes
Rating
8
–0.5
353
28
–0.5
3
1
–40 to 85
–40 to 125
–40 to 150
165
–65 to 165
Units
V
V
VAC
V
V
mA
mA
ºC
ºC
ºC
ºC
ºC
Typical Overcurrent Capabilities
1,2
Characteristic
Overcurrent
1
Test
Symbol
I
POC
Notes
T
A
= 25°C, 1s duration, 1% duty cycle
T
A
= 85°C, 1s duration, 1% duty cycle
T
A
= 150°C, 1s duration, 1% duty cycle
Rating
1200
900
600
Units
A
A
A
was done with Allegro evaluation board. The maximum allowed current is limited by T
J
(max) only.
2
For more overcurrent profiles, please see FAQ on the Allegro website, www.allegromicro.com.
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com