Presence Sensing Safety Devices
Safety Light Curtains
Point of Operation Control
Typical Wiring Diagrams (continued)
Outputs (Receiver)
The output voltage U
A
of each channel depends on the supply
voltage U
V
and the switched load and is at least
U
A
= U
V
- 2V
Both outputs OSSD1 and OSSD2 (OSSD = Output Signal
Switching Device) are control reliable, actively monitored PNP solid
state outputs. The outputs can carry a maximum of 0.5 Amps and
are short circuit protected. If the protected field is clear, the two
outputs are HIGH (active).
• An additional supply voltage must not be applied to the outputs.
4
POC Transmitter
1
3
+24V
I
max
= 0.5A
R
L
I
max
= 0.5A
R
L
5
6
2
0V
7
PE
RS 485
(440L-M8100/diagnostics)
ATTENTION:
Both output signals must
be processed separately. They must not be
connected in series or parallel.
Receiver connection diagram
RS-485 Communication Interface
This interface serves to communicate with the
440L-M8100
(optional). If the
440L-M8100
is not used, the connection is not
used.
1
6
5
2
3
7
POC Receiver
Inside View of Connector
Pin #1
Pin #2
Pin #3
Pin #7
Pin #1 = +24V
Pin #2 = Gnd
Pin #3 = OSSD1
Pin #4 = OSSD2
Pin #5 = Com- RS 485
Pin #6 = Com+ RS 485
Pin #7 = PE
Receiver Cable Plug
Pin
1
2
3
4
5
6
7
Color
Black
White
Blue
Brown
Grey
Yellow
Green
Function
+24V DC
0V DC
Out 1 OSSD 1
Out 2 OSSD 2
-RS 485 Communications
+RS 485 Communications
PE
4
POC Receiver
Top View of Connector
Pin #6
Pin #5
Internal
Connector
1
2
3
4
5
6
7
Mini
Plug
1
2
3
4
5
6
7
Pin #4
Receiver cable pin diagram
2-33