欢迎访问ic37.com |
会员登录 免费注册
发布采购

440N-S32037 参数 Datasheet PDF下载

440N-S32037图片预览
型号: 440N-S32037
PDF下载: 下载PDF文件 查看货源
内容描述: 非接触开关 [Non contact Switches]
分类和应用: 开关
文件页数/大小: 4 页 / 90 K
品牌: ALLEN-BRADLEY [ Allen-Bradley ]
 浏览型号440N-S32037的Datasheet PDF文件第2页浏览型号440N-S32037的Datasheet PDF文件第3页浏览型号440N-S32037的Datasheet PDF文件第4页  
Interlock Switches
Non contact Switches
Sipha Sensors
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119,
IEC60947-5-1, IEC/EN60947-5-3,
ANSI B11.19, AS4024.1
Rating dependent on control unit and
application.
CE marked for all applicable directives,
cULus and T
Ü
V
Make Break
5mm (0.20in) 11mm (0.43in)
9mm (0.35in) 12mm (0.47in)
5mm (0.20in) 12mm (0.47in)
10mm (0.39in) 13mm (0.51in)
300VDC, 250VAC, 0.5A including
inrush. 15VA/10W suitable for AC/DC
circuits
Category
Approvals
Maximum Safety Sensing
Distance
Style S1
Style S2
Style S3
Style S4
Description
With the increasing speed and complexity of applications a simple
magnetic switch may be insufficient to meet the increased risks,
therefore Sipha’s design incorporates several magnetically sensitive
elements which must be triggered in a particular sequence to operate
correctly. The Sipha sensor, designed to operate with its own
actuator, helps prevent defeatability by a simple magnet.
The Sipha with its moulded-in brackets and diminutive size, is
extremely versatile and simple to install. The Sipha Sensor must be
connected to the Sipha control unit giving a monitored circuit. For
high-risk applications the control unit is used with a single sensor to
give a high-integrity system. For other applications, multiple sensors
(including mechanical switches) can be connected to one Sipha
control unit. Sipha has facilities for connecting a manual reset button
and for monitoring external devices such as contactors.
Four types of sensors and actuators are available incorporating
different operating distances and physical sizes.
Auxiliary Contact Switching
Capability
Operating Temperature
S1, S2, S3 -10°C to +55°C (+14° to +131°F)
S4 (GD2) -25°C to +125°C (-13° to +257°F)
Enclosure Protection
S1, S2, S31 IP67 (NEMA 6P)
S4 (GD2) IP67 (NEMA 6P)
Cable
S1 0.54 mm
2
(20AWG) 4 wire
PVC Jacket OD – 4mm (0.16in)
S2
0.54 mm
2
(20AWG) 4 wire
PVC Jacket OD – 4mm (0.16in)
Cable
S1 0.54mm
2
(0.02in) (20AWG) 4 wire PVC
jacket OD—4mm (0.16in)
S2
0.54mm
2
(0.02in) (20AWG) 4 wire PVC
jacket OD—4mm (0.16in)
Case Material
S1, S2
S30 (Actuator)
S31 (Sensor)
S4 (GD2)
Mounting
Weight (not including cable)
S1
S2
S3
S4
Shock
Vibration
Moulded ABS
Polyester
Nylon (Trogamid)
Stainless Steel
Any Position
Sensor Actuator
18g (0.04lbs) 15g (0.03lbs)
20g (0.04lbs) 30g (0.07lbs)
18g (0.04lbs) 6g (0.01lbs)
150g (0.33lbs) 170g (0.37lbs)
30g, 11ms half-sine
1mm, 10 to 55Hz
Features
Non contact actuation
Magnetic coded sensing
Four housing styles
Must be operated with its own safety control unit
3-60