Presence Sensing Safety Devices
Safety Light Curtains
Perimeter Access Control
Maximum scanning range
Maximum beam gap
Minimum beam count
Maximum beam count
Minimum housing length
Maximum housing length
70m
500mm
1 beam
4 beams
320mm
1800mm
Specifications
Standards
Approvals
Protected Height
EN 50100
BG and CE marked for all applicable
directives
Depends on product selection
70m (225ft), single beam PAC 7.5m
Depends on product selection
IP 65
7-pin mini style on transmitter and 8-pin
on receiver
24V DC
±
20%
5 Vss
7 watts—Transmitter
6 watts—Receiver
Optical, without separate
synchronization channel
2 x PNP, 0.5 A, short circuit protected
Uv - 2V
Description
Multi-beam safety light curtains from Rockwell Automation are
infrared protection devices with 1 to 4 infrared beams. They operate
on the through-beam principle, consisting of a sender and receiver
unit and are suitable for access control and perimeter guarding.
The PAC fulfils the pr EN 50100 requirements, safety category 4, in
that it is a self monitoring device.
• Integrated evaluation with state-of-the-art electronics and
especially developed ICs (ASICs)
• Beam coding for high interference immunity
• Actively monitored semiconductor outputs
• Mini style quick disconnect connectors
• Fast response time
• Large signal reserve (factor 2)
• Optical synchronization of sender and receiver units
• Multiple safeguarding by means of corner mirrors and columns
• Operating modes:
• Electronic Device Monitoring (EDM)
• Restart Interlock
• Muting configuration available
The devices were designed for industrial applications and offer the
following advantages:
•
•
•
•
•
Beam coding for optimal interference immunity
Adaptability for safe PLC
Robust modular construction
Universal application possibilities
Simple installation
Scanning Range
Beam Gap
Enclosure Rating
Connection Type
Supply Voltage Uv
Maximum Residual Ripple
Power Consumption
Synchronization
Outputs
Minimum output voltage
Response Time
Protection
Connection
Max. wire cross section
Cable length
≤
20ms
Short circuit and overload
1.0mm
2
with jacket
1.5mm
2
without jacket
60m (196.8ft) maximum
Protection against over-voltage (
≥
1kV)
from Level 3 or higher (IEC 801 part 5;
2 kV)
between PE and +V.
Guard-only with manual restart
Type 4 (self-checking)
According to EN 50100
0°C to 55°C (32°F to 131°F)
15%...95% (not condensing)
-25°C to 70°C (-13°F to 158°F)
Length dependent upon protected
height; (see dimensional drawings)
52 mm x 55 mm (2.05in x 2.17in)
Mode of Operation
Safety Category
Requirement
Operating Ambient Temp.
Air Humidity
Storage Temperature
Approximate Dimensions
Height
Housing Cross Section
2-34