欢迎访问ic37.com |
会员登录 免费注册
发布采购

440T-MSRUE22 参数 Datasheet PDF下载

440T-MSRUE22图片预览
型号: 440T-MSRUE22
PDF下载: 下载PDF文件 查看货源
内容描述: 电磁释放器 [Solenoid Release Units]
分类和应用:
文件页数/大小: 2 页 / 100 K
品牌: ALLEN-BRADLEY [ Allen-Bradley ]
 浏览型号440T-MSRUE22的Datasheet PDF文件第2页  
Prosafe Trapped Key Interlock Switches
Solenoid Release Units
Specifications
Standards
EN292-1&2, EN1954-1, IEC/EN60204-1,
EN1088, IEC/EN60947-5-1, ISO13849-
1, ISO12100-1&2, ISO14119, GS-ET-19,
AS4024.1
Cat. 1 per EN 954-1 (ISO 13849-1)
Suitable for Cat. 2, 3, and 4 systems
BG, cULus and CE marked for all
applicable directives
24V DC, 110V AC, 230V AC, 110V DC
6.5W continuous
6VA continuous
See rotary power switches
Any position
15.1kN (3398lbs)
14Nm (124lb•in)
316L Stainless Steel
316L Stainless Steel
ABS Plastic
0.75sq. mm2 (18AWG) 2-wire PVC
jacket QD
0°C to +40°C (+32°F to +104°F)
95% RH
Category
Approvals
Solenoid Voltage
Solenoid Power
DC Types
AC Types
Electrical Characteristics
Mounting
Max Shear Force to Key
Max Torque to Key
Material
Trapped Key Components
Face Plate
Optional Box
Cable
Description
The solenoid release unit is used for electrical isolation of machinery
to enable safe access. It consists of a rotary power switch (RPS) and
a solenoid. The trapped key can be removed once an external signal
is given to its internal solenoid locking mechanism. An indicator
light on the SRU indicates when trapped key can be removed; that is,
when power is applied to the solenoid. The solenoid signal only
needs to be present when key removal is necessary. The solenoid is
rated for 100% duty cycle. Power to the solenoid can be removed
after the trapped key is removed.
Removing the trapped key causes the isolating power switch to
change state; the normally open contacts open and the normally
closed contacts (if applicable) will close.
The trapped key can then be used in the next sequence of the
operation.
Operating Temperature
Humidity
Environmental
With Optional Plastic IP65 (NEMA 13)
Enclosure
Electrical Life
>100,000
Mechanical Life
100,000
Features
Direct drive operation—positively opens contacts
Integral solenoid monitoring
Key trapped until release signal is applied
IP 65 enclosure or panel mounted versions
LED or NEON “key free” indication
316L stainless steel construction
24V DC, 110V AC/DC or 230V AC solenoid options
Weatherproof stainless steel dust cap as standard
UL and CSA approval on switches
Single or multiple key units available (contact factory)
Replaceable code barrel assembly
The Prosafe Advantage
Stainless steel
construction.
5-12