Prosafe Trapped Key Interlock Switches
Electronic Timed-Delay Units
Specifications
Standards
EN292-1&2, EN1954-1, IEC/EN60204-1,
EN1088, IEC/EN60947-5-1, ISO13849-
1, ISO12100-1&2, ISO14119, GS-ET-19,
AS4024.1
Cat. 3 per EN 954-1 (ISO 13849-1)
Suitable for Cat. 2, 3, or 4 systems
BG and CE marked for all applicable
directives
0°C to +40°C (32°F to +104°F)
95% RH
100,000
15.1kN (3398lbs)
14Nm (124lb•in)
316L Stainless Steel
316L Stainless Steel
ABS Plastic
Tamper resistant screws
2.0kg (4.4lbs)
24V DC, 110V AC and 230V AC
0.1 second to 40 minutes
Category
Approvals
Operating Temperature
Humidity
Mechanical Operations
Max. Shear Force to Key
Max. Torque to Key
Material
Trapped Key Components
Face Plate
Optional Box
Assembly Fixing
Weight
Inputs
Time Range
Description
The Electronic Timed-delay Unit (ETU) is used in applications that
require an elapsed time to occur before allowing access to a
hazardous area. The ETU uses a CU1 control unit timer to execute
the timing sequence. Turning a non removable key initiates the
timer. When the CU1 times out, its output energizes an internal
solenoid, which then allows the removal of either one or two
trapped keys.
The Single-key Timed delay Unit (STU) has one trapped key. After
the CU1 timer has expired, the single trapped key can be removed
and used to continue the next sequence in allowing access to the
hazard. The single key must be returned to the STU and trapped to
allow the non removable key to re-initiate the hazard.
The Dual-key Timed delay Unit (DTU) has two trapped keys. After
the CU1 timer has expired, both keys can be removed and used to
continue the next sequences in allowing access to the hazard. Both
keys must be returned to the DTU and trapped to allow the non
removable key re-initiate the hazard.
See the CU1 control unit for details on setting the delay time.
Features
Timed-delay output up to 40 minutes
Single key or Dual key
316L stainless steel keys
Category 1 Stop
Replaceable code barrel assembly
Optional IP65 enclosure
The Prosafe Advantage
Stainless steel
construction.