AS7C34098A
®
Recommended operating conditions
Parameter
Symbol
Min Typical
Max
Unit
V
Supply voltage
V
(10/12/15/20)
3.0
2.0
–0.5
0
3.3
–
3.6
CC
**
V
V
+ 0.5
CC
V
IH
Input voltage
*
V
–
0.8
70
85
V
IL
commercial
Ambient operating temperature
industrial
T
–
°C
°C
A
T
–40
–
A
*
**
VIL min = –1.0V for pulse width less than 5ns.
V
IH max = VCC + 2.0V for pulse width less than 5ns.
DC operating characteristics (over the operating range)1
–10
–12
–15
–20
Parameter Symbol
Test conditions
= Max
Min Max Min Max Min Max Min Max Unit
Input leakage
V
CC
|I |
–
1
–
1
–
1
–
1
µA
LI
current
V
= GND to V
IN CC
V
= Max
CC
Output leakage
current
CE = V or OE = V
IH IH
|I
|
–
1
–
1
–
1
–
1
µA
LO
or WE = V
IL
V
= GND to V
I/O
CC
Operating
power supply
current
Industrial
Commercial
–
-
180
170
–
-
160
150
–
-
140
130
–
-
110 mA
100 mA
V
= Max
CC
I
CC
CE ≤ V , f = f
I
= 0mA
IL
max OUT
V
= Max
CC
I
–
–
60
8
–
–
60
8
–
–
60
8
–
–
60 mA
SB
CE ≥ V , f = Max
IH
Standby power
supply current
V
= Max
CC
CE ≥ V – 0.2V, V ≥ V – 0.2V or
I
CC
IN
CC
8
mA
SB1
V
≤ 0.2V, f = 0
IN
V
I
= 8 mA, V = Min
–
0.4
–
–
0.4
–
–
0.4
–
–
0.4
–
V
V
OL
OL
CC
Output voltage
V
I
= –4 mA, V = Min
2.4
2.4
2.4
2.4
OH
OH
CC
Capacitance (f = 1MHz, T = 25° C, V = NOMINAL)2
a
CC
Signals
Parameter
Input capacitance
I/O capacitance
Symbol
Test conditions
= 0V
Max
Unit
pF
C
A, CE, WE, OE, UB, LB
I/O
V
6
8
IN
IN
C
V
= V = 0V
OUT
pF
I/O
IN
8/17/04,v. 2.1
Alliance Semiconductor