EP220 & EP224 Classic EPLDs  
AC Operating Conditions: -7 & -10 Speed Grades  
Combinatorial Mode  
Note (1)  
EP220-7  
EP224-7  
EP220-10  
EP224-10  
Symbol  
Parameter  
Min Max Min Max Units  
tPD1  
Input or I/O to non-registered output, inversion on, Note (2)  
Input or I/O to non-registered output, inversion off, Note (2)  
Input or I/O to output enable, Note (3)  
7.5  
8.5  
9
10  
10  
ns  
ns  
ns  
ns  
ps  
ps  
tPD2  
tPZX  
tPXZ  
tOSR  
tOSC  
10  
Input or I/O to output disable, Note (3)  
9
10  
Register mode output-to-output skew  
300  
400  
300  
400  
Combinatorial mode output-to-output skew  
EP220-7  
EP224-7  
EP220-10  
EP224-10  
Synchronous Clock Mode  
Symbol  
Parameter  
Min Max Min Max Units  
fMAX  
fCNT1  
fCNT2  
tSU1  
tH  
Maximum frequency (pipelined), no feedback, Note (2)  
Maximum counter frequency, external feedback, Note (2)  
Maximum counter frequency, internal feedback, Note (2)  
Input or I/O setup time to global clock  
Input or I/O hold time from global clock  
Global clock to output delay, Note (2)  
Global clock to output delay through combinatorial macrocell  
Minimum global clock period, Note (2)  
Clock low time  
100  
74  
100  
7
62.5  
58.8  
60.6  
10  
MHz  
MHz  
MHz  
ns  
0
0
ns  
tCO1  
tCO2  
tCNT  
tCL  
6.5  
11  
10  
7
ns  
13  
ns  
16.5  
ns  
4
4
7
7
ns  
tCH  
Clock high time  
ns  
tCP  
Clock period  
10  
16  
ns  
Notes to tables:  
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.  
(2) Measured with three I/O outputs switching.  
(3) The tPZX and tPXZ parameters are measured at ± 0.5 V from steady-state voltage that is driven by the specified  
output load. The tPXZ parameter is measured with CL = 5 pF and with all eight outputs switching.  
14  
Altera Corporation