DATA SHEET
Part Number: SL18
16004
Ordering Different Lead Types:
Inside Kinked Leads
Outside Kinked Leads
Not available
Use
–B
after Ametherm’s Part #
For example: to order an outside kinked lead use part number SL18
16004-B
D
D
D
T
B
L
S
STRAIGHT
LEADS
S
OUTSIDE
KINKED LEADS
S
INSIDE
KINKED LEADS
C
Resistance @ 25°C
Max Steady State Current Up to 65°C
Max Recommended Energy Rating
Actual Failure Point of Instantaneous Energy
Resistance @ 100 % of Maximum Current
Resistance @ 50% of Maximum Current
Body Temperature at Maximum Current
Dissipation Constant
Thermal Time Constant
Material Type
Maximum Capacitance @
120/240
VAC
16.0Ω
± 20%
4.0
A
75.0
J
150.0
J
0.270
Ω
0.650
Ω
180
°C
25
mW/°C
100
seconds
“H”
5000
µF/
1250
µF
D
T
Lead Diameter
S
L
Coating Run Down
Straight Leads
B
C
18.0
±
1.0
mm
5.1
± 0.5 mm
1.0± 0.1 mm
7.8 ±
1.0
mm
38.0 ±
5.0
mm
3.0mm Max
7.5
±
1.0
mm
3.85
± .5 mm
Revision Date
12/03/2004
Ametherm, Inc.
3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com