A62L256 Series
Recommended DC Operating Conditions
(T
A
= 0°C to + 70°C or -40°C to +85°C)
Symbol
VCC
GND
V
IH
V
IL
Parameter
Supply Voltage
Ground
Input High Voltage
Input Low Voltage
Min.
2.7
0
VCC * 0.7
-0.3
Typ.
3.0
0
-
0
Max.
3.6
0
VCC + 0.3
+0.3
Unit
V
V
V
V
Absolute Maximum Ratings*
VCC to GND . . . . . . . . . . . . . . . . . . . . . -0.5V to +3.6V
IN, IN/OUT Volt to GND . . . . . . . . . -0.5V to VCC + 0.5V
Operating Temperature, Topr . . . . . . . . . . 0°C to +70°C
Storage Temperature, Tstg . . . . . . . . . -55°C to +125°C
Power Dissipation, P
T
. . . . . . . . . . . . . . . . . . . . . 0.7W
Soldering Temp. & Time . . . . . . . . . . . . . 260°C, 10 sec
*Comments
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied and exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
DC Electrical Characteristics
(T
A
= 0°C to + 70°C or -40º C to +85º C, VCC = 2.7V to 3.6V, GND = 0V)
Symbol
Parameter
A62L256-55LL/55LLU
Min.
I
LI
Input Leakage
Current
Output Leakage
Current
Dynamic
Operating Current
-
Typ.
-
Max.
1
A62L256-70LL/70LLU
Min.
-
Typ.
-
Max.
1
µA
V
IN
= GND to VCC
Unit
Conditions
I
LO
-
-
1
-
-
1
µA
CE = V
IH
or WE = V
IL
V
I/O
= GND to VCC
Min. Cycle, Duty = 100%
CE = V
IL
, I
I/O
= 0mA
CE = V
IL
, V
IH
= VCC
V
IL
= 0V, f = 1 MHz
I
I/O
= 0 mA
I
CC1
-
*18
25
-
**12
20
mA
I
CC2
Dynamic
Operating Current
-
1
3
-
1
3
mA
Typical values are measured at VCC = 3.0V, T
A
= 25°C and not 100% tested.
* Testing condition : T
A
= 25°C, VCC = 3.0V, Cycle Time = 55 ns
** Testing condition : T
A
= 25°C, VCC = 3.0V, Cycle Time = 70 ns
PRELIMINARY
(November, 2001, Version 1.4)