LP621024D-I Series
Recommended DC Operating Conditions
(TA = -40°C to + 85°C)
Symbol
Parameter
Supply Voltage
Min.
4.5
0
Typ.
Max.
Unit
5.0
5.5
V
GND
VIH
Ground
0
3.5
0
0
V
V
Input High Voltage
Input Low Voltage
Output Load
2.2
-0.3
-
VCC + 0.3
VIL
+0.8
30
1
V
CL
-
pF
-
TTL
Output Load
-
-
Absolute Maximum Ratings*
*Comments
VCC to GND ............................................. -0.5V to + 7.0V
IN, IN/OUT Volt to GND....................-0.5V to VCC + 0.5V
Operating Temperature, Topr .................. -40°C to + 85°C
Storage Temperature, Tstg.................... -55°C to + 125°C
Temperature Under Bias, Tbias............... -10°C to + 85°C
Power Dissipation, PT .......................................................................0.7W
Soldering Temp. & Time .............................260°C, 10 sec
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to this device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied or intended. Exposure to the absolute
maximum rating conditions for extended periods may
affect device reliability.
DC Electrical Characteristics (TA = -40°C to + 85°C, VCC = 5V ± 10%, GND = 0V)
LP621024D-55LLI
LP621024D-70LLI
Symbol
Parameter
Unit
Conditions
Min.
Max.
Min.
Max.
Input Leakage
Current
-
1
-
1
VIN = GND to VCC
çILIú
mA
mA
CE1 = VIH or CE2 = VIL
Output Leakage
Current
-
-
1
-
-
1
çILOú
ICC
or OE = VIH or WE = VIL
VI/O = GND to VCC
Active Power
Supply Current
CE1 = VIL, CE2 = VIH
II/O = 0mA
15
15
mA
Min. Cycle, Duty = 100%
CE1 = VIL, CE2 = VIH
II/O = 0mA
ICC1
ICC2
-
-
70
15
-
-
70
15
mA
mA
Dynamic
Operating
Current
CE1 = VIL, CE2 = VIH
VIH = VCC, VIL = 0V
f = 1MHZ, II/O = 0mA
PRELIMINARY (August, 2002, Version 0.0)
4