LP621024D-I Series
Recommended DC Operating Conditions
(T
A
= -40°C to + 85°C)
Symbol
Parameter
Supply Voltage
GND
V
IH
V
IL
C
L
TTL
Ground
Input High Voltage
Input Low Voltage
Output Load
Output Load
Min.
4.5
0
2.2
-0.3
-
-
Typ.
5.0
0
3.5
0
-
-
Max.
5.5
0
VCC + 0.3
+0.8
30
1
Unit
V
V
V
V
pF
-
Absolute Maximum Ratings*
VCC to GND ............................................. -0.5V to + 7.0V
IN, IN/OUT Volt to GND ....................-0.5V to VCC + 0.5V
Operating Temperature, Topr .................. -40°C to + 85°C
Storage Temperature, Tstg.................... -55°C to + 125°C
Temperature Under Bias, Tbias............... -10°C to + 85°C
Power Dissipation, P
T .......................................................................
0.7W
Soldering Temp. & Time .............................260°C, 10 sec
*Comments
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to this device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied or intended. Exposure to the absolute
maximum rating conditions for extended periods may
affect device reliability.
DC Electrical Characteristics
Symbol
Parameter
(T
A
= -40°C to + 85°C, VCC = 5V
±
10%, GND = 0V)
LP621024D-55LLI
Min.
Max.
1
LP621024D-70LLI
Min.
-
Max.
1
µA
V
IN
= GND to VCC
CE1 = V
IH
or CE2 = V
IL
or OE = V
IH
or WE = V
IL
V
I/O
= GND to VCC
CE1 = V
IL
, CE2 = V
IH
I
I/O
= 0mA
Min. Cycle, Duty = 100%
CE1 = V
IL
, CE2 = V
IH
I
I/O
= 0mA
CE1 = V
IL
, CE2 = V
IH
V
IH
= VCC, V
IL
= 0V
f = 1MH
Z,
I
I/O
= 0mA
Unit
Conditions
I
LI
Input Leakage
Current
-
I
LO
Output Leakage
Current
Active Power
Supply Current
-
1
-
1
µA
I
CC
-
15
-
15
mA
I
CC1
Dynamic
Operating
Current
-
70
-
70
mA
I
CC2
-
15
-
15
mA
PRELIMINARY
(August, 2002, Version 0.0)
4
AMIC Technology, Inc.