AS1907/AS1908/AS1909
Data Sheet - A p p l i c a t i o n I n f o r m a t i o n
8 Application Information
Negative Going V
CC
Transients
All devices are effectively immune to short-duration, negative-going V
CC
transients (glitches). The Maximum Transient
Duration vs. Reset Comparator Overdrive graph
shows the maximum pulse width that a negative-going
V
CC
transient may typically have without issuing a reset signal. As the amplitude of the transient increases, the maxi-
mum allowable pulse width decreases.
Valid Reset Output
If V
CC
falls below 1V and approaches the minimum operating voltage of 0.7V, push/pull-type reset sinking/sourcing
capabilities greatly decrease. High-impedance CMOS-logic inputs connected to RESET can drift to indeterminate volt-
ages, although this is normally not a problem since most microprocessors do not operate at V
CC
< 1V.
For the AS1908, where RESET must be valid to V
CC
= 0, a 100kΩ pull-up resistor between RESET and V
CC
will hold RESET high if V
CC
falls below 0.7V.
For the AS1907, where RESET must be valid down to 0V, add a pull-down resistor between RESET and GND
to eliminate stray leakage currents and hold RESET low. A pull-down resistor of 100kΩ is large
enough not to load RESET yet small enough to pull it low.
Since the AS1909 has an open-drain, active-low output, it typically uses a pull-up resistor. With this device, RESET will
most likely not maintain an active condition, but will drift to a non-active level due to the pull-up resistor and the
reduced sinking capability of the open drain device. Therefore, this device is not recommended for applications where
the RESET pin is required to be valid down to V
CC
= 0.
Table 5. Reset Thresholds
Reset Thresholds
T
AMB
= +25ºC
Suffix
25
24
23
22
21
20
19
18
17
16
Min
2.478
2.378
2.279
2.180
2.081
1.982
1.883
1.784
1.685
1.586
Typ
2.50
2.40
2.30
2.20
2.10
2.00
1.90
1.80
1.70
1.60
Max
2.523
2.422
2.321
2.220
2.119
2.018
1.917
1.816
1.715
1.614
T
AMB
= -40 to +125ºC
Min
2.43
2.33
2.23
2.13
2.04
1.94
1.84
1.75
1.65
1.55
Max
2.58
2.47
2.37
2.27
2.18
2.06
1.96
1.85
1.75
1.65
Bi-Directional Microprocessor Interface
The RESET output on the AS1909 is open-drain, thus this device can interface easily with microprocessors that have
bi-directional reset pins, such as the Motorola 68HC11.
Connect the RESET output of this device directly to the microprocessor’s RESET I/O pin with a single pull-up resistor
to allow either device to assert reset
Layout Considerations
The devices require proper layout and design procedures for optimum performance.
!
!
!
Short, wide traces should be used to reduce stray inductance and capacitance.
Bypass capacitors should be as close to the device as possible.
Large ground planes should be used wherever possible.
www.austriamicrosystems.com
Revision 1.05
7 - 10