ATS278
Two Phase Hall Effect Latch With FG Output
Magnetic Characteristics(
Ta=+25
o
C)
(1mT=10 Gauss)
A grade
Characteristic
Operate Point
Release Point
Hysteresis
B grade
Characteristic
Operate Point
Release Point
Hysteresis
DOB
Symbol
B
OP
B
RP
B
HYS
Min.
10
-60
-
Typ.
-
-
75
Max.
60
-10
-
Unit
Gauss
Gauss
Gauss
Symbol
B
OP
B
RP
B
HYS
Min.
5
-80
-
Typ.
-
-
75
DO
Max.
80
-5
-
Unit
Gauss
Gauss
Gauss
Output Voltage in Volts
RP
OFF
Output Voltage in Volts
12
10
8
6
4
2
OFF
12
10
8
6
4
2
OP
ON
OP
Vsat
RP
Vsat
-200
-100
0
ON
-200
-100
0
100
200
100
200
Magnetic Flux Density in Gauss
Magnetic Flux Density in Gauss
Anachip Corp.
www.anachip.com.tw
4/6