ATA7609
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
DC Power Supply (V
EE
)
Storage Temperature
DC Input Current
ESD Sensitivity (Human Body Model)
MIN
-7.0
-65
-
100
MAX
1.0
125
5.0
-
UNIT
V
°C
mA
V
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Table 3: Recommended Operating Conditions
PARAMETER
Operating Voltage Range
Operating Temperature Range
Die Attach Temperature
Photodiode Capacitance (PIN + stray)
Photodiode Responsivity
Photodiode Contact Resistance
Input Bondwire Inductance
(1)
MIN
-5.50
-40
-
-
-
-
0.7
TYP
-5.2
-
-
0.225
0.92
10
1.0
MAX
-4.90
85
260
0.3
-
15
-
UNIT
V
o
C
C
o
pF
A/W
Ω
nH
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical
specifications.
Notes:
(1) Defined at the interface between the die and the substrate.
PRELIMINARY DATA SHEET - Rev 1.0
10/2002
3