AWT6314R
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
Supply Voltage (V
CC
)
With RF Drive
DC Only
Mode Control Voltage (V
MODE
)
Reference Voltage (V
REF
)
RF Input Power (P
IN
)
Storage Temperature (T
STG
)
MIN
0
0
0
0
-
-40
MAX
+5
+8
+3.5
+3.5
+10
+150
UNIT
V
V
V
dBm
°C
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure
to absolute ratings for extended periods of time may adversely affect
reliability.
Table 3: Operating Ranges
PARAMETER
Operating Frequency (f)
Supply Voltage (V
CC
)
Reference Voltage (V
REF
)
Mode Control Voltage (V
MODE
)
RF Output Power (P
OUT
)
Case Temperature (T
C
)
MIN
824
1850
+3.2
+2.75
0
+2.5
0
30.5
(1)
27.5
(1)
-30
TYP
-
+3.4
+2.85
-
+2.85
-
31.0
28.0
-
MAX
849
1910
+4.2
+3.1
+0.5
+3.1
+0.5
-
-
+85
UNIT
MHz
V
V
V
dBm
°C
PA "on"
PA "shut down"
Low Bias Mode
High Bias Mode
AMPS
CDMA
COMMENTS
Cellular
PCS
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Notes:
(1) For operation at V
CC
= +3.2 V, P
OUT
is derated by 0.5 dB.
Data Sheet - Rev 2.0
09/2008
3