AWT6631
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
Supply Voltage (V
CC
)
Battery Voltage (V
BATT
)
Control Voltages (V
MODE1
, V
ENABLE
)
RF Input Power (P
IN
)
Storage Temperature (T
STG
)
MIN
0
0
0
-
-40
MAX
+5
+6
+3.5
+10
+150
UNIT
V
V
V
dBm
°C
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
Supply Voltage (V
CC
)
Battery Voltage (V
BATT
)
Enable Voltage (V
ENABLE
)
Mode Control Voltage (V
MODE1
)
Case Temperature (T
C
)
MIN
+0.5
+3.1
+1.35
0
+1.35
0
-30
TYP
+3.4
+3.4
+1.8
0
+1.8
0
-
MAX
+4.35
+4.35
+3.1
+0.5
+3.1
+0.5
+90
UNITS
V
V
V
V
°C
COMMENTS
P
OUT
≤
+28.25 dBm
P
OUT
≤
+28.25 dBm
PA “on”
PA “shut down”
Low Bias Mode
High Bias Mode
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
3
Data Sheet - Rev 2.7
03/2012