欢迎访问ic37.com |
会员登录 免费注册
发布采购

A7BC70ZA 参数 Datasheet PDF下载

A7BC70ZA图片预览
型号: A7BC70ZA
PDF下载: 下载PDF文件 查看货源
内容描述: 单节锂离子/锂聚合物单节锂离子/锂聚合物 [Single-cell Li-ion / Li-polymer Single-cell Li-ion / Li-polymer]
分类和应用:
文件页数/大小: 23 页 / 223 K
品牌: ANASEM [ AnaSem Hong Kong Limited ]
 浏览型号A7BC70ZA的Datasheet PDF文件第1页浏览型号A7BC70ZA的Datasheet PDF文件第2页浏览型号A7BC70ZA的Datasheet PDF文件第4页浏览型号A7BC70ZA的Datasheet PDF文件第5页浏览型号A7BC70ZA的Datasheet PDF文件第6页浏览型号A7BC70ZA的Datasheet PDF文件第7页浏览型号A7BC70ZA的Datasheet PDF文件第8页浏览型号A7BC70ZA的Datasheet PDF文件第9页  
Single-cell Li-ion / Li-polymer Battery Protection IC
Rev. E09-06
A7B Series
PRODUCTS NUMBERING GUIDE
A7B
0V battery charge function
A : Acceptable
B : Unacceptable
Detection delay time
Serial code from A to Z
A : Standard value
B to Z : Depend upon selected value by customer
Detection voltage
Serial code from 00 to 99
* Depend upon selected value by customer
Delivery form
C : Chip in tray
W : 5 inches wafer
E : SOT-26
N : SON-5
STANDARD MODELS LINE-UPS
Model No.
Selectable items
Over-charge detection voltage
1)
Over-charge hysteresis voltage
2)
3)
4)
5)
A7BE01AA
4.275V
0.20V
2.300V
–0.100V
0.100V
1.0s
31.0ms
6)
A7BE02AA
4.280V
0.20V
2.300V
–0.100V
0.100V
1.0s
31.0ms
8.0ms
Acceptable
A7BE03AA
4.290V
0.20V
2.300V
–0.100V
0.100V
1.0s
31.0ms
8.0ms
Acceptable
A7BE04AA
4.325V
0.25V
2.500V
–0.150V
0.150V
1.0s
31.0ms
8.0ms
Acceptable
Over-discharge detection voltage
Charge over-current detection voltage
Over-charge detection delay time
6)
6)
Discharge over-current detection voltage
Over-discharge detection delay time
0V battery charge function
1)
2)
Charge over-current detection delay time
8.0ms
Acceptable
Note : The value of detection voltage and delay time can be changed by customer’s request.
For details, please contact us.
The over-charge detection voltage can be selected in the range 4.0V to 4.5V in 5mV steps.
The over-charge hysteresis voltage can be selected in the range 0.0V to 0.4V in 50mV steps.
3)
The over-discharge detection voltage can be selected in the range 2.0V to 3.0V in 5mV steps.
4)
The charge over-current detection voltage can be selected in the range –0.25V to –0.05V in 5mV steps.
5)
The discharge over-current detection voltage can be selected in the range 0.05V to 0.40V in 5mV steps.
6)
The delay time can be changed within the value listed below.
Delay time
Over-charge detection delay time
Over-discharge detection delay time
Charge over-current detection delay time
* The value in bold is set for standard products
Symbol
tc
tdc
tic
0.125s
31ms
8.0ms
Selectable value
1.0s
125ms
125ms
1.0s
3.75s
2
.......... Future of the analog world
AnaSem Inc.