APL5610/A
Ordering and Marking Information
APL5610
APL5610A
Assembly Material
Handling Code
Temperature Range
Package Code
APL5610 C:
APL5610A C:
L10X
LA0X
Package Code
C : SOT-23-6
Operating Ambient Temperature Range
I : -40 to 85
o
C
Handling Code
TR : Tape & Reel
Assembly Material
G : Halogen and Lead Free Device
X - Date Code
X - Date Code
Note: ANPEC lead-free products contain molding compounds/die attach materials and 100% matte tin plate termination finish; which
are fully compliant with RoHS. ANPEC lead-free products meet or exceed the lead-free requirements of IPC/JEDEC J-STD-020D for
MSL classification at lead-free peak reflow temperature. ANPEC defines “Green” to mean lead-free (RoHS compliant) and halogen
free (Br or Cl does not exceed 900ppm by weight in homogeneous material and total of Br and Cl does not exceed 1500ppm by
weight).
Absolute Maximum Ratings
(Note 1 )
Symbol
V
CC
V
FB
V
DRV
T
J
T
STG
T
SDR
EN, POK, to GND Voltage
FB to GND Voltage
DRV to GND Voltage
Maximum Junction Temperature
Storage Temperature
Maximum Lead Soldering Temperature, 10 Seconds
Parameter
VCC Input Voltage (VCC to GND)
Rating
-0.3 to 15
-0.3 to 7
-0.3 to 7
-0.3 to V
CC
+0.3
150
-65 to 150
260
Unit
V
V
V
V
o
C
C
C
o
o
Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Thermal Characteristic
Symbol
θ
JA
Parameter
Junction-to-Ambient Resistance in Free Air
(Note 2)
SOT-23-6
Typical Value
250
Unit
o
C/W
Note 2:
θ
JA
is measured with the component mounted on a high effective thermal conductivity test board in free air.
Recommended Operating Conditions
(Note 3)
Symbol
V
CC
V
EN
V
OUT
T
A
T
J
EN to GND Voltage
VOUT Output Voltage
(Note4)
Ambient Temperature
Junction Temperature
Parameter
VCC Input Voltage (VCC to GND)
Range
4.5 to 13.5
0 to 5.5
0.8 ~ V
IN
- V
DROP
-40 to 85
-40 to 125
Unit
V
V
V
o
o
C
C
Note 3: Refer to the typical application circuit.
Note 4: V
DROP
defined as the V
IN
-V
OUT
voltage at V
OUT
= 98% normal V
OUT
. The linear regulator must provide the output MOSFET with
sufficient Gate-to-Source voltage (V
GS
= V
CC
- V
OUT
) to regulate the output voltage.
Copyright
©
ANPEC Electronics Corp.
Rev. A.4 - Sep., 2009
2