EXQ50 Series
DC/DC CONVERTERS
OUTPUT
POWER
(MAX.)
36W
50W
50W
50W
Notes
1
Single output
36-50W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
33-75VDC
33-75VDC
33-75VDC
33-75VDC
OVP
2.3VDC
3.0VDC
3.9VDC
6.0VDC
OUTPUT
VOLTAGE
1.8V
2.5V
3.3V
5.0V
OUTPUT
CURRENT
(MIN.)
0A
0A
0A
0A
OUTPUT
CURRENT
(MAX.)
20A
20A
15A
10A
EFFICIENCY
(TYP.)
86.5%
88.0%
89.0%
90.0%
REGULATION
LINE
±0.3%
±0.3%
±0.3%
±0.3%
(10)
LOAD
±0.3%
±0.3%
±0.3%
±0.3%
MODEL
NUMBER
(7)
EXQ50-48S1V8
EXQ50-48S2V5
EXQ50-48S3V3
EXQ50-48S05
PROTECTION
Short circuit protection
Overvoltage protection
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
(<20mΩ short)
Continuous
Non-latching clamp
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
2
The EXQ50 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 120 for details.
3
Recommended input fusing is a 3.15A HRC 200V rated fuse.
4
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5
Measured with no external Pi filter. Significant reduction possible with
external filter.
6
Start-up into resistive load.
7
Active low remote On/Off is available. Standard product is active high.
When ordering active low parts, designate with the Suffix '-R', e.g
EXQ50-48S3V3-R.
8
This parameter is calculated at worst case line, load, temperature and
initial settings.
9
This is inclusive of the output trim range. If 6.0% trim-up is used, for
example, then only 4.0% output sense is available.
10
Maximum, not typical, specification.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
2.300±0.020 (58.42±0.5)
0.400±0.017 (10.18±0.44)
Installed HT
PIN CONNECTIONS
PIN NUMBER
1
2
3
4
5
6
7
8
FUNCTION
+Vin
On/Off
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
Remote
on/off
Sense+
Trim
Sense-
Vin-
Vout-
Top view
0.017 (0.43)
Min clearance
Seating Plane
0.138 (3.50) REF
2.000 (50.80)
0.140 (3.56)
ø0.040
±0.002
(ø1.04
±0.05)
6 Places
Vin-
Remote
on/off
Vout-
Sense-
Trim
Sense+
Vout+
0.150 (3.81)
ø0.062
±0.002
(ø1.57
±0.05)
2 Places
0.300 (7.62)
0.450 (11.43)
0.150 (3.81)
0.300 (7.62)
Bottom view
All dimensions in inches (mm)
All tolerances
±0.010in
(±0.25mm)
Unless otherwise stated
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV
TÜV Product Service. Certificate No. B 01 11 38572 029
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
File Name: EXQ50S.PDF Rev: 01 Nov 2002
0.435 (11.05)
0.435
(11.05)
0.300 (7.62)
0.600 (15.24)
Vin+
1.450±0.020
(36.83±0.5)
Vin+
Vout+