LDO06C Series | 6 A DC-DC
C Class Non-Isolated DC/DC Converter
3.3 V, 5 V, 12 V Model
2.5 V Setpoint
Input Characteristics
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input current - operating
(Source) (3.3 V)
(Sink) (3.3 V)
(Source) (5 V)
(Sink) (5 V)
(Source) (12 V)
(Sink) (12 V)
Input capacitance - internal
filter
Input capacitance - external
filter
Iin
Iin
Iin
Iin
Iin
Iin
Cinput
Cbypass
4.25
-4.10
2.78
-2.71
1.10
-1.08
22
1
Adc
Adc
Adc
Adc
Adc
Adc
µF
µF
Vin = Vin (nom); Iout = Iout
(max); Vo = V0 (nom)
Internal to converter
Recommended customer
added capacitance
3.3 V, 5 V, 12 V Model
2.5 V Setpoint
Electrical Charateristics
- O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Line regulation
Load regulation
Vo (nom)
2.475
2.500
2.525
±0.2
±0.5
Vdc
%
%
Vin = Vin (nom); Iout = Iout
(nom)
Iout = Iout (nom); Vin (min) to
Vin (max)
Vin = Vin (nom); Iout (min) to
Iout (max)
Output current - continuous
Output current - short circuit
Iout
Isc
0
13.5
6.0
Adc
Apk
Continuous, unit auto recovers
from short
Output voltage - noise Vrms
(3.3 V) Vp-p
(5.0 V) Vp-p
(12 V) Vp-p
20
25
35
mV pk-pk
mV pk-pk
mV pk-pk
Measurement band width
20 MHz
See Application Note 186 for
details
3.3 V, 5 V, 12 V Model
2.5 V Setpoint
Electrical Charateristics
- O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Load transient response -
park deviation
Load transient response
- recover
External load capacitance
Vdynamic
130
mV
Peak deviation for 50% to
100% step load, di/dt =
10 A/s
Settling time to within 1% of
output set point voltage for
50% to 75% step load
See Application Notes 186 for
output capitance values vs.
stability
Trecovery
8
µs
Cext
0
3500
µF
8