LX200 SERIES
Flexible single and muliple outputs
200W continuous, 300W peak output power
Industry standard footprint, low profile
Conducted noise to meet EN55022 class B
AC and DC input voltage options in same package
Efficiency up to 88%
Optional power sharing/VME signals board
Autoranging input option
[ 2 YEAR WARRANTY ]
The LX200 series offers 200 Watts of continuous output power in a low profile
industry standard footprint. With two single output options and a flexible
multiple output version, the series can address most power requirements as
standard. The design is specifically tailored to allow full flexibility and
modifications to meet customer applications can be implemented with relative
ease. The LX200 AC input series meets the safety requirements of EN60950,
VDE0805, UL1950 and CSA C22.2 No. 950. Input conducted noise levels meet
the requirements of FCC and EN55022 class B. LX200 series power supplies
are ideal for use in applications such as point-of-sale equipment, central and
public telecom power systems and network equipment.
SPECIFICATION
OUTPUT SPECIFICATIONS
Voltage adjustability
Remote sense
Line regulation
(LL to HL, FL)
Load regulation
(20% to 100% FL)
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
-8%/+16%
±20%
±10%
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, level A
EN55022, level B
EN61000-4-2, level
EN61000-4-2, level
EN61000-4-5, level
EN61000-4-4, level
EN61000-4-3, level
EN61000-4-6, level
Vout on singles
+5V output on multiple
Single outputs
Multiple: +5V output
Multiple: aux. outputs, Note 5
Single outputs:
Multiple: +5V output
Multiple: -5V output
Multiple: ±12V, 24V, Note 5
5A load step on main output
Auxiliary outputs, Note 5
25% di/dt
±0.2%
±0.2%
±0.5%
±0.2%
±1.0%
±4.0%
±2.0%
1.0%
3
4
3
3
3
3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
criteria
criteria
criteria
criteria
criteria
criteria
1
1
1
1
2
2
GENERAL SPECIFICATIONS
Hold-up time
Efficiency
110/230VAC
28ms
82% min.
Input/output
Input/chassis
Fixed
3000VAC
1500VAC
44kHz
Cross regulation
Transient response
Isolation voltage
Switching frequency
Approvals and
standards
Weight
1% max. dev., 1ms recov.
±0.02%/°C
±0.04%/°C
EN60950, VDE0805, UL1950
See Note 7
CSA C22.2 No. 950
1.3kg (46oz)
Temperature coefficient Main/single output
Multiple: auxiliary outputs
Overvoltage protection
Output power limit
Main/single output
130% ±10% Vout
Multiples:
300W Pout
primary power limited
Singles:
105%-120% Iout
current foldback
All outputs
Yes
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0°C to +70°C
Non-operating
–25°C to +85°C
0°C to +40°C ambient,
200W
convection cooled
40°C to 70°C ambient, Derate linearly
convection cooled
to 25% full load
Peak (0°C to 40°C, max. 10s)
300W
Non-condensing
Operating
Non-operating
5% to 95% RH
10,000 feet max.
30,000 feet max.
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
See Note 3
LX200-46xx models, 175 to 264VAC
(230VAC version)
LX200-76xx models,
98 to 132VAC
autorange version
190 to 264VAC
Drop-out voltage
90VAC
50Hz/60Hz
25A max.
115VAC, 60Hz
230VAC, 50Hz
1.6mA
2.5mA
Logic 0 on ROF
Vibration
Relative humidity
Altitude
Input frequency
Input surge current
Safety ground
leakage current
Remote OFF
Operating, 5–50Hz
0.05mm pk-pk
Operating, 50–100Hz 0.025mm pk-pk
Non-operating
100mm drop on
chassis face
PAGE 1