NLP110 Medical Series
S i n g l e a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
TOTAL
MODEL
PEAK (4)
RIPPLE (5)
MIN (6)
0.5A
0.3A
0A
MAX (1)
15A
150LFM (2) 300LFM (3)
REGULATION
NUMBERS
+5V
+12V
22A
9.2A
2.3A
4.6A
16A
16A
1.0A
16A
16A
1.0A
8.5A
16A
1.0A
8.5A
16A
1.0A
22A
9.2A
2.3A
4.6A
18A
20A
1A
22A
11.5A
2.5A
6.0A
18A
50mV
120mV
240mV
240mV
50mV
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
5.0%
2.0%
2.0%
5.0%
2.0%
2.0%
5.0%
2.0%
2.0%
5.0%
NLP110-9905
NLP110-9912
NLP110-9917
NLP110-9924
NLP110-9993
6.4A
1.6A
3.2A
13A
+48V
+24V
0.2A
0.5A
0.2A
0A
+5V (A)
+3.3V (B)
+12V
13A
20A
50mV
0.65A
13A
1.0A
22A
120mV
50mV
+3.3V (A)
+2.5V (B)
+12V
0.5A
0.1A
0A
20A
20A
1A
NLP110-9994
13A
22A
50mV
0.65A
6.5A
13A
1.0A
10A
120mV
1200mV
50mV
+12V (A)
+3.3V (B)
-12V
0.2A
0.5A
0A
8.5A
20A
1A
NLP110-9995 (7)
NLP110-9908 (7)
22A
0.65A
6.5A
13A
1.0A
10A
120mV
120mV
50mV
+12V (A)
+5V (B)
-12V
0.2A
0.2A
0A
8.5A
18A
1A
22A
0.65A
1.0A
120mV
Notes
N
6
1
2
3
Free air convection.
Minimum load required for correct start-up and operation on single
outputs and on main output of multiple versions. Failure to observe
minimum load on main output will not allow the supply to start-up
correctly. Some electronic test loads have a large delay time before they
start drawing current even though the voltage from the supply is present.
During this time delay, there is no load on the output and as a result, the
supply cannot start-up properly and maintain its correct output voltage.
In these instances, a dummy resistive load across the output may be
necessary to load the output of the supply until the test load can function
correctly and draw the intended minimum load. Minimum load required
on auxiliary outputs to maintain regulation.
Multiple output units: maximum continuous output power not to exceed
80W.
For -9993; I3.3V = 13A max.; I5.0V = 13A max.; I3.3V + I5.0V ≤ 16A.
For -9994; I3.3V = 13A max.; I2.5V = 13A max.; I3.3V + I2.5V ≤ 16A
For -9995; I3.3V = 13A max.; I12V = 6.5A max.; I3.3V + I12V ≤ 16A.
For -9908; I5.0V = 13A max.; I12V = 6.5A max.; I5.0V + I12V ≤ 16A.
Single output units: maximum continuous output power not to exceed;
75W on –9905; 76.8W on –9912,-9924, and –9917.
150LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed
105W.
7
For models NLP110-9908 and NLP110-9995, the 12V output is floating.
For -12V output, pin 11 on J2 has to be connected to Return making pin
12 the -12V output
For -9993; I3.3V = 16A max.; I5.0V = 16A max.; I3.3V + I5.0V ≤ 20A.
For -9994; I3.3V = 16A max.; I2.5V = 16A max.; I3.3V + I2.5V ≤ 20A
For -9995; I3.3V = 16A max.; I12V = 8.5A max.; I3.3V + I12V ≤ 20A.
For -9908; I5.0V = 16A max.; I12V = 8.5A max.; I5.0V + I12V ≤ 20A.
Single output units: maximum continuous output power not to exceed
110W for all models.
8
9
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
For optimum reliability, no part of the heatsink should exceed 110oC, and
no semiconductor case temperature should exceed 120oC.
300LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed
110W.
10 CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
12 The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond
each edge, using an unshielded cable. No external filtering required
during conducted emissions testing but some applications may require
additional filtering to achieve system compliance. A line choke, (AC input
cords looped twice through an EMI suppression toroid) was used during
radiated emissions testing. Considerable radiated testing in 1U six-sided
boxes has shown that units can meet level B in typical systems.
Application support is available from the factory to assist with EMI
compliance.
For -9993; I3.3V = 20A max.; I5.0V = 18A max.; I3.3V + I5.0V ≤ 22A.
For -9994; I3.3V = 20A max.; I2.5V = 20A max.; I3.3V + I2.5V ≤ 22A
For -9995; I3.3V = 20A max.; I12V = 8.5A max.; I3.3V + I12V ≤ 22A.
For -9908; I5.0V = 20A max.; I12V = 8.5A max.; I5.0V + I12V ≤ 22A.
Single output units: maximum continuous output power not to exceed
110W for all models.
4
5
Peak output current lasting less than 30 seconds with duty cycle less
than 5%. During peak loading, output voltage may exceed total
regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20MHz bandwidth using a 6” twisted
pair, terminated with a 10µF electrolytic capacitor and a 0.1µF ceramic
capacitor.
13 All models require a minimum mounting stand-off of 6.35mm (0.25
inches) in the end use product.
International Safety Standard Approvals
VDE0750/IEC60601-1 and EN60601-1
UL2601-1 and C22.2 No. 601.1-M90.
www.artesyn.com
File Name: NLP110M.PDF Rev: 13 Dec 2002