PTH05050
5 Vin single output
DC-DC CONVERTERS
POLA Non-isolated
NEW Product
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
90
TEMPERATURE (ºC)
80
EFFICIENCY (%)
70
60
50
40
30
20
0
1
2
3
4
5
6
OUTPUT CURRENT (A)
Figure 1 - Safe Operating Area
Vin = 5 V, Output Voltage = 3.3 V (See Note A)
100LFM
Nat conv
100
90
80
70
60
50
40
Vout
3.3V
2.5V
1.8V
1.2V
0.8V
0
1
2
3
4
5
6
OUTPUT CURRENT (A)
Figure 2 - Efficiency vs Load Current
Vin = 5 V (See Note B)
Notes
Track
1
2
Vin
3
4
C
in
100µF
(Required)
+
R
SET
1%, 0.1W
(Required)
6
Vout
A
SOA curves represent the conditions at which internal components are
within the Artesyn derating guidelines.
B
Characteristic data has been developed from actual products tested at
25 °C. This data is considered typical data for the converter.
PTH05050
(Top View)
5
C
o1
100µF
Electrolytic
(Optional)
+
C
o2
10µF
Ceramic
(Optional)
Inhibit
GND
GND
Figure 3 - Standard Application
File Name: pth05050.pdf Rev (06): 16 Dec 2005