12 Vin single output
DC-DC CONVERTERS
POLA Non-isolated
NEW Product
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
PTH12010W Characteristic Data
PTH12010
90
TEMPERATURE (ºC)
TEMPERATURE (ºC)
80
70
60
50
40
30
20
0
2
4
6
8
10
12
OUTPUT CURRENT (A)
Figure 1 - Safe Operating Area
Vin = 12 V, Output Voltage = 5 V (See Note A)
Nat conv
100 LFM
200 LFM
400 LFM
90
80
70
60
50
40
30
20
0
2
4
6
8
10
12
OUTPUT CURRENT (A)
Figure 2 - Safe Operating Area
Vin = 12 V, Output Voltage = 3.3 V (See Note A)
Nat conv
100 LFM
200 LFM
400 LFM
90
TEMPERATURE (ºC)
80
EFFICIENCY (%)
70
60
50
40
30
20
0
2
4
6
8
10
12
OUTPUT CURRENT (A)
Figure 3 - Safe Operating Area
Vin = 12 V, Output Voltage ≤ 1.8 V (See Note A)
Nat conv
100 LFM
200 LFM
400 LFM
100
90
80
70
60
50
40
0
2
4
6
8
10
12
Vout
5.0V
3.3V
2.5V
2.0V
1.8V
1.5V
1.2V
OUTPUT CURRENT (A)
Figure 4 - Efficiency vs Load Current
Vin = 12 V (See Note B)
Notes
Track
Margin Down
Margin Up
10
1
9
8
7
A
SOA curves represent the conditions at which internal components are
within the Artesyn derating guidelines.
B
Characteristic data has been developed from actual products tested at
25 °C. This data is considered typical data for the converter.
PTH12010
(Top View)
V
in
2
6
V
out
Inhibit
3
4
5
V
o
Sense
+
C
in
560µF
(Required)
R
SET
1%, 0.1W
(Required)
+
C
out
330µF
(Optional)
L
O
A
D
GND
GND
Figure 5 - Standard Application
File Name: pth12010.pdf Rev (07): 19 Dec 2005