SXA10 Series
| 15W DC/DC
SIL05E Series | 5 A DC-DC Converter
E Class Non-Isolated
Note 1
Thermal reference is defined as the highest temperature
measured at any one of the specified thermal reference points.
See Figure 9: Thermal Reference Points.
Thermal Ref Points
Note 2
The Remote ON/OFF pin is referenced to ground.
Note 3
The SIL05E features a ‘Negative Logic’ Remote ON/OFF
operation. If not using the Remote ON/OFF pin, leave the pin
open (the converter will be on). The Remote ON/OFF pin is
referenced to ground.
The following conditions apply for the SIL05E:
Configuration
Converter Operation
Unit is ON
Remote pin open circuit
Remote pin pulled low
Unit is ON
Direction of Airflow
Remote pin pulled high [Von/off >2.5V] Unit is OFF
A ‘Positive Logic’ Remote ON/OFF version is also possible
with this converter. To order please place the suffix ‘-R’ at the
end of the model number, e.g. SIL05E-05W3V3-VRJ.
Figure 9: Thermal Reference Points
Note 4
Thermal reference set up: Unit mounted on an edge card test
board 203mm x 190mm. Test board mounted vertically. For test
details and recommended set-up see Application Note 142.
Note 5
Max 69ºC for full load in still air.
Note 6
For SIL05E-05W3V3 minimum operating voltage is 4.5V,
for Vo = 3V3
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
10